Shear strengthening of sub-standard reinforced concrete beams with CFRP: Influence of fiber areal weight, wrap scheme and concrete strength

dc.authorid0000-0003-1578-4461
dc.authorid0000-0002-1834-902X
dc.authorid0000-0002-5744-251_
dc.authorid0000-0002-5410-9218
dc.contributor.authorArslan, Musa Hakan
dc.contributor.authorAlav, Deniz Sarı
dc.contributor.authorUysal, Yusuf
dc.contributor.authorAksoylu, Ceyhun
dc.date.accessioned2026-03-11T06:53:31Z
dc.date.issued2025
dc.departmentMeslek Yüksekokulları, Dursunbey Meslek Yüksekokulu
dc.descriptionAlav, Deniz Sarı (Balikesir Author)
dc.description.abstractThis study investigates the effectiveness of carbon fiber-reinforced polymer (CFRP) in enhancing the performance of reinforced concrete beams with insufficient shear reinforcement-a common issue in existing low- and highstrength reinforced concrete buildings. A total of 35 one-third scale beams were tested under four-point bending, considering varying concrete strengths (5–70 MPa), CFRP areal weights (300 and 900 g/m²), and wrapping configurations (full (F), U-shaped (U), and side (S)). Key parameters such as load–displacement behavior, energy dissipation, ductility, and stiffness were analyzed in detail. The results demonstrated that CFRP strengthening increased shear capacity by up to 154 % in low-strength concrete (5–20 MPa), while the improvement was limited to 47.2 % in high-strength concrete. Failure modes were significantly influenced by wrapping type: full wrapping led to a 90 % shift from shear to flexural failure, whereas U-shaped and side wrapping achieved only 40 % and 10 % conversion, respectively. Full wrapping also yielded the highest gains in energy dissipation and ductility, while side wrapping alone was largely ineffective. Interestingly, increasing CFRP areal weight did not result in proportional performance gains; in many cases, the 300 g/m² application outperformed the 900 g/m² variant. This suggests that poor interfacial bonding and inadequate epoxy impreg nation may hinder the effectiveness of higher areal weight configurations. In conclusion, concrete strength, wrapping type, and CFRP areal weight must be considered collectively in shear strengthening strategies. Among these, full wrapping offers the most consistent and reliable improvements in shear capacity, ductility. and energy dissipation.
dc.identifier.doi10.1016/j.istruc.2025.110734
dc.identifier.endpage20
dc.identifier.issn2352-0124
dc.identifier.scopus2-s2.0-105025525821
dc.identifier.scopusqualityQ1
dc.identifier.startpage1
dc.identifier.urihttp://doi.org/10.1016/j.istruc.2025.110734
dc.identifier.urihttps://hdl.handle.net/20.500.12462/23446
dc.identifier.volume82
dc.identifier.wosWOS:001630796500002
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofStructures
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCFRP Strengthening
dc.subjectWrap Configuration
dc.subjectExperimental Study
dc.subjectConcrete Strength
dc.subjectReinforced Concrete Beams
dc.titleShear strengthening of sub-standard reinforced concrete beams with CFRP: Influence of fiber areal weight, wrap scheme and concrete strength
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
deniz-sari-alav.pdf
Boyut:
12.15 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: