Voltammetric determination of boron by using Alizarin Red S
| dc.authorid | 0000-0002-5527-6472 | en_US |
| dc.contributor.author | Şahin, İbrahim | |
| dc.contributor.author | Nakiboğlu, Nuri | |
| dc.date.accessioned | 2019-10-17T10:25:43Z | |
| dc.date.available | 2019-10-17T10:25:43Z | |
| dc.date.issued | 2006 | en_US |
| dc.department | Fakülteler, Necatibey Eğitim Fakültesi, Matematik ve Fen Bilimleri Eğitimi Bölümü | en_US |
| dc.department | Fakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümü | en_US |
| dc.description | Şahin, İbrahim (Balıkesir Author) | en_US |
| dc.description.abstract | A novel voltammetric method for boron determination in ppb level is described. Boron complexes with Alizarin Red S (ARS) and the complex, as well as the free ligand, both adsorbs on a hanging mercury drop electrode. The method is based on the monitoring the anodic peak of the complex at -0.47 V in ammonium acetate-phosphate buffer (pH 7). The maximum peak current was obtained by scanning the potential from -700 mV versus Ag/AgCl to more positive potentials without accumulation in the presence of 1 x 10(-6) mol L-1 of ARS. The instrumental parameters were mainly differential pulse mode with a pulse duration of 0.02 s and a scan rate of 5 mV s(-1). The limit of detection based on signal to ratio of 3 was calculated as 15 jig L-1. The calibration plot for boron was linear in the range of 0-500 mu g L-1. The interference of various ions was examined and serious interference was observed from antimony(III). The relative standard deviation was found to be 5.1% for the 100 mu g L-1 boron level (n = 10). The method was applied to the determination of boron in water and seawater samples with high boron content. The results obtained from the developed method were compared with Azomethine-H-method and no statistically significant difference was found. | en_US |
| dc.identifier.doi | 10.1016/j.aca.2006.05.049 | |
| dc.identifier.endpage | 258 | en_US |
| dc.identifier.issn | 0003-2670 | |
| dc.identifier.issn | 1873-4324 | |
| dc.identifier.issue | 2 | en_US |
| dc.identifier.scopus | 2-s2.0-33745685647 | |
| dc.identifier.scopusquality | Q1 | |
| dc.identifier.startpage | 253 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.aca.2006.05.049 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12462/8057 | |
| dc.identifier.volume | 572 | en_US |
| dc.identifier.wos | WOS:000239234900013 | |
| dc.identifier.wosquality | Q1 | |
| dc.indekslendigikaynak | Web of Science | |
| dc.indekslendigikaynak | Scopus | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier Science Bv | en_US |
| dc.relation.ispartof | Analytica Chimica Acta | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/embargoedAccess | en_US |
| dc.subject | Boron | en_US |
| dc.subject | Voltammetry | en_US |
| dc.subject | Alizarin Red S | en_US |
| dc.title | Voltammetric determination of boron by using Alizarin Red S | en_US |
| dc.type | Article | en_US |












