Treatment of olive mill wastewater with electro-oxidation method
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
Özet
Advanced oxidation processes are an efficient method of treating many industrial wastewaters. This study investigated the treatment of olive mill wastewater with the electro-oxidation method. This study investigated data obtained from chemical oxygen demand (COD), total organic carbon (TOC) and total phenol (TP) removal efficiencies for this wastewater. The anode material was Ti/Pt while the cathode material was Ti. The experiments using a batch reactor examined the effects of mixing rate (0-600 rpm), dilution factor (1/5-5/5), pH (2-8), type of support electrolyte (Na2SO4, KCl and NaCl), concentration of support electrolyte (0.25-1.25 M) and current density (2.5-15 mA/cm(2)) on COD, TOC and TP removal efficiencies. The study found the COD, TOC and TP removal rates under optimum conditions were 100%, 78% and 100%.