Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorYıldız, Yusuf
dc.contributor.authorCaner, İsmail
dc.contributor.authorİlten, Nadir
dc.contributor.authorKaraoğlan, Aslan Deniz
dc.date.accessioned2019-07-30T13:29:54Z
dc.date.available2019-07-30T13:29:54Z
dc.date.issued2018en_US
dc.identifier.urihttps://doi.org/10.1680/jensu.16.00001
dc.identifier.urihttps://hdl.handle.net/20.500.12462/5718
dc.description.abstractThis study analysed current daylighting conditions in terms of luminous comfort in the classrooms of Balikesir University in Turkey. This was managed through a questionnaire survey and numerical simulations in 16 different classrooms of the Faculty of Engineering-Architecture. The simulation study considered the differences in the performance parameters daylighting level, illuminance uniformity and daylighting factors in order to compare them with the values defined in the standards. Collected for the survey were 818 questionnaires, and these were analysed to understand the students' perception of luminous comfort in classrooms by using SPSS 22.0 and Minitab 16. The simulation results showed that performance factors in all classrooms were lower than the standard values. Therefore, daylighting can be necessary together with artificial lighting based on the distance from window at the same time. This result revealed that design of artificial lighting is as significant as the design of classrooms. According to the survey results, the perception of luminous comfort is mostly affected by orientation, distance from windows and difference in gender. Furthermore, the students mostly preferred both natural and artificial lighting. This matched well with the simulation results. In conclusion, this paper proposes guidelines for designing high-performance classrooms in terms of luminous comfort.en_US
dc.language.isoengen_US
dc.publisherIce Publishingen_US
dc.relation.isversionof10.1680/jensu.16.00001en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDesign Methods & Aidsen_US
dc.subjectEnergyen_US
dc.subjectStatistical Analysisen_US
dc.titleField study to analyse luminous comfort in classroomsen_US
dc.typearticleen_US
dc.relation.journalProceedings of The Institution of Civil Engineers-Engineering Sustainabilityen_US
dc.contributor.departmentMimarlık Fakültesien_US
dc.contributor.authorID0000-0002-3 255-6850en_US
dc.contributor.authorID0000-0003-1 232-649Xen_US
dc.contributor.authorID0000-0003-4 009-5078en_US
dc.contributor.authorID0000-0002-3 292-5919en_US
dc.identifier.volume171en_US
dc.identifier.issue3en_US
dc.identifier.startpage151en_US
dc.identifier.endpage165en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster