Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDündar, Rıza
dc.contributor.authorKulduk, Erkan
dc.contributor.authorSoy, Fatih Kemal
dc.contributor.authorKılavuz, Ahmet Erdem
dc.contributor.authorSakarya, Engin Umut
dc.contributor.authorYazıcı, Haşmet
dc.contributor.authorEren, Abdülkadir
dc.date.accessioned2019-05-16T19:33:18Z
dc.date.available2019-05-16T19:33:18Z
dc.date.issued2014
dc.identifier.issn2146-3840
dc.identifier.urihttps://hdl.handle.net/20.500.12462/4308
dc.descriptionYazıcı, Haşmet (Balikesir Author)en_US
dc.description.abstractAmaç: Bu çalışmada hava yolu tonal ABR ile saf ses hava yolu işitme eşiklerinin karşılaştırılması yapılarak; klasik odyometrik yöntemlerle ileri ve çok ileri derece sensörinöral (S/N) işitme kaybı olan kişilerin tonal ABR ile elde edilen eşiklerinin korelasyonu araştırılmıştır. Yöntem: İleri ve çok ileri derece S/N işitme kaybı olan 80 hasta çalışmaya dahil edildi. Saf ses ölçümlerinde ileri ve çok ileri derecede sensörinöral işitme kaybı hastaların 500, 2000 ve 4000 Hz'te elde edilen saf ses hava yolu eşikleri ile tonal-ABR eşik değerleri arasında karşılaştırma yapıldı. Bulgular: Çalışmaya alınan hastaların yaş ortalaması 21.8±3.45 olarak saptandı ve tüm hastalar erkekti. Tonal ABR ve saf ses eşikleri arasında 500 Hz uyaran için ortalama fark 4.75 dB, 2000 Hz uyaran için 6.25 dB ve 4000 Hz uyaran için fark 4.87 dB bulunmuştur. Sonuç: Sonuç olarak ileri derece S/N işitme kaybı olan bireylerde saf ses odyometri eşikleri ile 500, 2000 ve 4000 Hz tonal ABR V.dalga ile elde edilen elektrofizyolojik eşikler arasında güçlü bir korelasyon vardır. Tonal ABR, saf ses odyometri yapılamadığı durumlarda, işitme kaybı olan hastaların tanısında güvenilir bir test olarak kullanılabilir.en_US
dc.description.abstractObjective: In the present study, thresholds of airway tone-burst auditory brainstem response (ABR), and pure-tone audiometry were compared, and correlations between threshold values obtained with classical audiometric methods, and pure-tone airway hearing in individuals with advanced, and very advanced sensorineural (S/N) hearing loss were investigated. Methods: Eighty patients with advanced and very advanced S/N hearing loss were included in the study. Pure-tone air conduction thresholds of advanced, and very advanced S/N hearing loss patients detected at 500, 2000 and 4000 Hz frequencies were compared with tone-burst ABR threshold values. Results: Our study population consisted of males with a mean age of 21.8±3.45. Mean differences between thresholds of tone-burst, and pure-tone audiometry were detected to be 4.75 dB, 6.25 dB, and 4.87 dB at stimulus frequencies of 500 Hz, 2000 Hz, and 4000 Hz, respectively. Conclusion: In conclusion, in patients with S/N hearing loss, a strong correlation is found between pure-tone audiometry thresholds, and electrophysiological thresholds obtained at 500, 2000, and 4000 Hz with tone-evoked ABR wave-V. Tone-ABR can be used as a reliable test in the diagnosis of patients with hearing loss in conditions where pure-audiometry cannot be performed.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGenel ve Dahili Tıpen_US
dc.subjectPure-Tone Audiometryen_US
dc.subjectAdvanced Sensorineural Typehearing Lossen_US
dc.titleComparison of hearing thresholds of patients with advanced, and very advanced sensorineural type hearing loss using tone-evoked ABRen_US
dc.title.alternativeİleri ve çok ileri derece sensörinöral (S/N) işitme kaybı olan hastaların işitme eşiklerinin tonal ABR ile karşılaştırılmasıen_US
dc.typearticleen_US
dc.relation.journalJournal of Medical Updatesen_US
dc.contributor.departmentTıp Fakültesien_US
dc.identifier.volume4en_US
dc.identifier.issue2en_US
dc.identifier.startpage52en_US
dc.identifier.endpage55en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster