Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖner, Poyraz Alper
dc.contributor.authorDoğan, Seydi
dc.contributor.authorGürkan, Serkan
dc.contributor.authorKarapınar, Mustafa
dc.date.accessioned2024-01-18T10:26:31Z
dc.date.available2024-01-18T10:26:31Z
dc.date.issued2022en_US
dc.identifier.issn2146-0574 / 2536-4618
dc.identifier.urihttps://doi.org/10.21597/jist.998055
dc.identifier.urihttps://hdl.handle.net/20.500.12462/13818
dc.descriptionÖner, Poyraz Alper (Balikesir Author)en_US
dc.description.abstractA multi-channel measurement system used to measure electrocardiogram (ECG), electroencephalogram (EEG), electromyogram (EMG) and electrooculogram (EOG) biosignals has been designed and prototyped. The designed system has 16 configurable measurement channels. Of the 16 channels the developed system has, 8 have been designed for EEG, 2 for EMG, 2 for EOG, 1 for ECG measurements, the remaining 3 have been reserved as backup channels. In circuit design, biosignal amplifier design principles have been applied by taking into account the characteristics of the biosignal to be measured for each channel, such as bandwidth, frequency, amplitude, noise level. Modules such as instrumentation amplifier, filter, DC suppression unit, amplifier, DC level determination unit, analog digital converter, optical isolation unit, power supply have been designed to perform biosignal measurements through these channels. Biosignals measured by the developed system can be shifted to the desired threshold level with the help of the analog output reference voltage, converted to digital data 10-bit resolution and transferred to the computer environment in real time. The data transferred to the computer can be used in C#, Excel, MATLAB, and LabVIEW platforms. The novelty of the developed system is that any of the four desired biosignal types can be measured from any channel. In addition, another feature of the system is that it can work with real-time data without being dependent on the databases serving for human-computer interface applications. In experimental studies with some researchers for the performance tests of the system, ECG, EEG, EMG and EOG signals have been recorded with different module configurations, and signal processing stages were carried out to be used for human-computer applications.en_US
dc.language.isoengen_US
dc.publisherIğdır Üniversitesien_US
dc.relation.isversionof10.21597/jist.998055en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiomedical Engineeringen_US
dc.subjectBiosignal Measurementen_US
dc.subjectBiomedical Instrumentationen_US
dc.subjectHuman-Computer Interfacesen_US
dc.subjectHuman-Machine Interfacesen_US
dc.subjectEmbedded Systemsen_US
dc.titleDevelopment of a multichannel bioinstrumentation system for human-computer interface applicationsen_US
dc.typearticleen_US
dc.relation.journalIğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisien_US
dc.contributor.departmentMühendislik Fakültesien_US
dc.contributor.authorID0000-0001-5490-4599en_US
dc.contributor.authorID0000-0001-9785-4990en_US
dc.contributor.authorID0000-0003-2229-3361en_US
dc.contributor.authorID0000-0002-1953-6804en_US
dc.identifier.volume12en_US
dc.identifier.issue1en_US
dc.identifier.startpage182en_US
dc.identifier.endpage193en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster