Redefining the morphometry of subclavian vessels for clavicle fracture treatments

dc.authorid0000-0002-3632-1020en_US
dc.contributor.authorVatansever, Alper
dc.contributor.authorDemiryürek, Deniz
dc.contributor.authorErçakmak, Burcu
dc.contributor.authorÖzsoy, Hakan
dc.contributor.authorHazırolan, Tuncay
dc.contributor.authorŞentürk, Yunus Emre
dc.date.accessioned2020-01-09T12:09:13Z
dc.date.available2020-01-09T12:09:13Z
dc.date.issued2019en_US
dc.departmentFakülteler, Tıp Fakültesi, Temel Tıp Bilimleri Bölümüen_US
dc.descriptionVatansever, Alper (Balikesir Author)en_US
dc.description.abstractPurposeClavicle fractures are common injuries in adults and children. Although neurovascular damage is rarely seen, acute subclavian artery pseudoaneurysms and injuries to subclavian vessels were reported for closed fractures of the clavicle. The aim of this study was to identify the morphological details of the subclavian vessels and their relation to the sternoclavicular joint and body of the clavicle.Methods127 patients (66 females and 61 males) were evaluated using reconstructed three-dimensional computed tomographic angiographies. The point at which the subclavian artery crossed posterior to the clavicle was detected as a landmark. The medio-lateral distance between the sternal end of the clavicle, landmark, antero-posterior distance between the clavicle and the subclavian artery, diameter of the artery and vein, angle between the subclavian artery and vein, distance of the subclavian vein to the subclavian artery and the clavicle at the landmark were measured. Measurements were compared according to gender and right and left sides, and age correlation was determined.ResultsMorphometric relationship between the subclavian vessels and clavicle presented differences between genders. We measured the antero-posterior distance between the subclavian artery and the clavicle to be less than 1cm (0.91cm).ConclusionThe subclavian artery travelled longer distances in men than women to reach the point that it crossed the clavicle. Our results demonstrated that the subclavian artery does not pass from the inferior margin of the clavicle, thus, superior plate osteosynthesis does not have any risk to injury against the subclavian vessels during the management of the clavicle fractures.en_US
dc.identifier.doi10.1007/s00276-018-2132-z
dc.identifier.endpage372en_US
dc.identifier.issn0930-1038
dc.identifier.issn1279-8517
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85056001061
dc.identifier.scopusqualityQ2
dc.identifier.startpage365en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12462/10363
dc.identifier.volume41en_US
dc.identifier.wosWOS:000461368300002
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherSpringer Franceen_US
dc.relation.ispartofSurgical and Radiologic Anatomyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectSubclavian Vesselsen_US
dc.subjectClavicleen_US
dc.subjectComputed Tomographyen_US
dc.subject3D Reconstructionen_US
dc.titleRedefining the morphometry of subclavian vessels for clavicle fracture treatmentsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Vatansever2019_Article_RedefiningTheMorphometryOfSubc.pdf
Boyut:
967.73 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: