Seismic strengthening of improperly repaired reinforced concrete columns using CFRP confinement

dc.contributor.authorElçi, Hasan
dc.date.accessioned2021-02-25T10:38:25Z
dc.date.available2021-02-25T10:38:25Z
dc.date.issued2020en_US
dc.departmentFakülteler, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.description.abstractYIn this study, lack of strength, stiffness, energy dissipation and ductility characteristics of the improperly repaired RC square columns were examined and the recoverability of seismic performance with the external Carbon Fiber Reinforced Polymer (CFRP) confinement was investigated. A total of six RC columns were tested for three times with different test stages; as-built, improperly repaired with Normal Strength Concrete (NSC) and retrofitted with CFRP confinement. In the first tests, relatively high axial load (0.40A(c)f(c)) and cyclic lateral load up to 15% lateral strength loss were applied to expose heavy damage on test columns. After that, the damaged columns repaired by using NSC and retested under the same loading conditions. In the first two test stages, the drift ratio at the end of tests was approximately 5%. The lateral strength, stiffness, ductility and energy dissipation characteristics of the improperly repaired columns dramatically decreased. At the last stage tests, the stiffness of strengthened columns was considerably reduced due to the damage that occurred in the concrete core after the two pre-damage phases. The lateral strengths of the CFRP retrofitted columns did not change much compared to the as-built columns because of the quality of the repairing concrete (26 MPa and 54 MPa) and the strain hardening behavior of steel reinforcement. Compared to the as-built columns, the cumulative energy dissipation capacities of columns were significantly increased, however, ductility increase was not achieved for all specimens because of the dramatic loss of stiffness.en_US
dc.description.sponsorshipBalikesir University 2016/13en_US
dc.identifier.doi10.1016/j.istruc.2020.08.072
dc.identifier.endpage275en_US
dc.identifier.issn2352-0124
dc.identifier.scopus2-s2.0-85090360461
dc.identifier.scopusqualityQ1
dc.identifier.startpage266en_US
dc.identifier.urihttps://doi.org/10.1016/j.istruc.2020.08.072
dc.identifier.urihttps://hdl.handle.net/20.500.12462/11093
dc.identifier.volume28en_US
dc.identifier.wosWOS:000595314500002
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherElsevier Sci Incen_US
dc.relation.ispartofStructuresen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectReinforced Concrete Columnsen_US
dc.subjectRepairen_US
dc.subjectStrengtheningen_US
dc.subjectSeismic Behavioren_US
dc.subjectCFRP Stripsen_US
dc.titleSeismic strengthening of improperly repaired reinforced concrete columns using CFRP confinementen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
hasan-elci.pdf
Boyut:
14.34 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: