Novel Biometric Approach Based on Diaphragmatic Respiratory Movements Using Single-Lead EMG Signals

dc.authoridEraslan, Beyza/0000-0003-3190-5198
dc.contributor.authorEraslan, Beyza
dc.contributor.authorGorur, Kutlucan
dc.contributor.authorTemurtas, Feyzullah
dc.date.accessioned2025-07-03T21:26:27Z
dc.date.issued2023
dc.departmentBalıkesir Üniversitesi
dc.description.abstractThis study aims to develop a respiratory-based biometric approach that predict the identities of individuals using electromyography (EMG) signals generated from diaphragm movements. Therefore, the examination of these signals is effective and offer a development of biometric systems. Researchers use bioelectric signals for biometric authentication. Electromyography (EMG), one of these signals, is a muscle-based signal used in many areas. This signal provides biometrics such as taking precautions against forgery and meeting security requirements. To the best of our knowledge, this is the first study to investigate a respiratory-based biometric approach using EMG signals from a single-lead generated by diaphragm movements. Statistical feature extraction techniques, including RMS, STD, MAV, and VAR, were performed usingshallow classifiers. Moreover, Recurrent Neural Network (RNN)-based deep learning models were also implemented after the time-series data augmentation process against the overfitting problem and multi-session issues of data recording. As known, deep learning models need high-size data to obtain better performances in pattern recognition. As far as we know, this study is the first attempt to investigate data augmentation with RNN-based deep models for the diaphragmatic respiratory movement-based biometric system performance. In this study, the highest accuracy of 90.9% was obtained for training models using the EMG data of seven people in statistical feature-trained shallow models. Furthermore, RNN-based deep models have reached up to >96% accuracy in the testing phase. The framework of a Probabilistic Neural Network with a 2D-reshaped pattern has the greatest correct recognition rate over >99 accuracies among seven people in a diverse cross-validation strategy.
dc.identifier.doi10.1080/03772063.2023.2176368
dc.identifier.endpage4893
dc.identifier.issn0377-2063
dc.identifier.issn0974-780X
dc.identifier.issue8
dc.identifier.scopusqualityQ2
dc.identifier.startpage4872
dc.identifier.urihttps://doi.org/10.1080/03772063.2023.2176368
dc.identifier.urihttps://hdl.handle.net/20.500.12462/21745
dc.identifier.volume69
dc.identifier.wosWOS:000933013400001
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherTaylor & Francis Ltd
dc.relation.ispartofIete Journal of Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250703
dc.subjectBiometric identification
dc.subjectData augmentation
dc.subjectDiaphragmatic respiration
dc.subjectEMG
dc.subjectShallow and Deep Models
dc.subjectSingle-lead
dc.titleNovel Biometric Approach Based on Diaphragmatic Respiratory Movements Using Single-Lead EMG Signals
dc.typeArticle

Dosyalar