Effectivity Comparison Between Mechanical ChestCompression and Manual Chest Compression in Real UrbanTraffic

dc.contributor.authorSerin, Suha
dc.contributor.authorCaglar, Bahadir
dc.date.accessioned2025-07-03T21:10:52Z
dc.date.issued2020
dc.departmentBalıkesir Üniversitesi
dc.description.abstractObjective: The most significant factor that increases the survival rate in out-of-hospital sudden cardiac arrest cases is cardiopulmonary resuscitation, which is started early and performed effectively. The present study aims to compare the effectiveness of manuel chest compressions applied by healthcare workers to the effectiveness of a mechanical chest compression device in an ambulance moving in real urban traffic. Materials and Methods: The thirty healthcare workers were asked to perform chest compressions in different chest wall stiffnesses on manikin in ambulance. During chest compressions, the ambulance was continuously under way in real urban traffic. Then, a mechanical chest compression device was placed on the manikin and chest compressions were performed under the same conditions. Average speeds and depths of chest compressions for each cycle were recorded with a computer program. Results: The median chest compression depths of healthcare workers group and mechanical chest compression device group were 52 mm and 55 mm at 6 nm chest wall stiffness and 42 mm and 51 mm at 11 nm nm chest wall stiffness. When the number of compressions per minute was examined, the median value was 102 /min in both groups at 6 nm chest wall stiffness and 85 /min and 101/min at 11 nm chest wall stiffness.Conclusion: Mechanical chest compression device provides more effective chest compression during transport when compared to manual compression. The effectiveness of mechanical chest compression increases in patients with high body mass index.
dc.identifier.endpage197
dc.identifier.issn1308-9315
dc.identifier.issn2148-8797
dc.identifier.issue3
dc.identifier.startpage193
dc.identifier.trdizinid424551
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/424551
dc.identifier.urihttps://hdl.handle.net/20.500.12462/19899
dc.identifier.volume34
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.relation.ispartofFırat Üniversitesi Sağlık Bilimleri Tıp Dergisi
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_TR_20250703
dc.subjectAcil Tıp
dc.subjectTemel Sağlık Hizmetleri
dc.subjectSağlık Bilimleri ve Hizmetleri
dc.titleEffectivity Comparison Between Mechanical ChestCompression and Manual Chest Compression in Real UrbanTraffic
dc.typeArticle

Dosyalar