Flow-controlled thermal response test and its comparison with the conventional test methods

dc.authorid0000-0001-9740-2273en_US
dc.authorid0000-0002-7431-5115en_US
dc.contributor.authorAydın, Murat
dc.contributor.authorDölcek, Ayşe Özdoğan
dc.contributor.authorOnur, Mustafa
dc.contributor.authorŞişman, Altuğ
dc.date.accessioned2025-01-21T10:55:03Z
dc.date.available2025-01-21T10:55:03Z
dc.date.issued2024en_US
dc.departmentFakülteler, Mühendislik Fakültesi, Jeoloji Mühendisliği Bölümüen_US
dc.descriptionDölcek, Ayşe Özdoğan (Balikesir Author)en_US
dc.description.abstractA novel flow-controlled (FC) thermal response test (TRT) system is introduced to resolve the recently addressed inconsistency between the constant heat flux (CHF) and constant temperature (CT) TRTs. FC-TRT allows us to keep both inlet and outlet temperatures constant and improve the accuracy of CT-TRT. Using the FC-TRT system, four types of TRT experiments are performed, providing CT, CHF, and constant inlet temperature conditions, besides the novel one keeping both temperature and heat flux constant. Thermal conductivities from these TRT measurements are compared, and a good agreement is observed. FC-TRT offers higher accuracy and various TRT applications in one platform.en_US
dc.description.sponsorshipBalikesir Universityen_US
dc.identifier.doi10.1016/j.geothermics.2024.103011
dc.identifier.endpage11en_US
dc.identifier.issn0375-6505
dc.identifier.issn1879-3576
dc.identifier.issueJuneen_US
dc.identifier.scopus2-s2.0-85189759730
dc.identifier.scopusqualityQ1
dc.identifier.startpage1en_US
dc.identifier.urihttps://doi.org/10.1016/j.geothermics.2024.103011
dc.identifier.urihttps://hdl.handle.net/20.500.12462/15862
dc.identifier.volume120en_US
dc.identifier.wosWOS:001219600900001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherElsevier Ltden_US
dc.relation.ispartofGeothermicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectThermal Response Testen_US
dc.subjectBorehole Heat Transferen_US
dc.subjectGround Source Heat Pumpsen_US
dc.subjectFlow-Controlled Thermal Testen_US
dc.titleFlow-controlled thermal response test and its comparison with the conventional test methodsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
ayse-ozdogan-dolcek.pdf
Boyut:
7.6 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: