Gamma-ray-shielding parameters of some phantom fabrication materials for medical dosimetry

dc.authorid0000-0002-2869-664Xen_US
dc.contributor.authorÇelen, Yonca Yahşi
dc.date.accessioned2022-02-28T11:04:39Z
dc.date.available2022-02-28T11:04:39Z
dc.date.issued2021en_US
dc.departmentFakülteler, Tıp Fakültesi, Temel Tıp Bilimleri Bölümüen_US
dc.description.abstractRadiation has been used in many different fields since its discovery, but using it in medical applications is vital, as it is related to human health. In medical application, many different materials are used for different purposes. Three-dimensional materials are used in phantom technology, and it is important to know the properties of those materials. In this study, the linear attenuation coefficients (LACs; mu, cm(-1)) and some other related parameters of gamma rays (mean free path, half-value layer, tenth-value layer, effective atomic number (Z(eff)), electron density (N-eff) and equivalent atomic number (Z(eq))) were obtained for five different phantom fabrication materials used in medical dosimetry. The calculations were done using the Phy-X/PSD software for gamma energies of 10(-3)-10(5) MeV. The obtained LAC results ranged from 0.103 to 0.13 cm(-1) for 0.365 MeV, from 0.09 to 0.11 cm(-1) for 0.511 MeV and from 0.059 to 0.076 cm(-1) for 1.275 MeV.en_US
dc.identifier.doi10.1680/jemmr.21.00043
dc.identifier.endpage313en_US
dc.identifier.issn2046-0147
dc.identifier.issn2046-0155
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-85100991618
dc.identifier.scopusqualityQ2
dc.identifier.startpage307en_US
dc.identifier.urihttps://doi.org/10.1680/jemmr.21.00043
dc.identifier.urihttps://hdl.handle.net/20.500.12462/12054
dc.identifier.volume10en_US
dc.identifier.wosWOS:000702741300010
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherICE Publishingen_US
dc.relation.ispartofEmerging Materials Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiomaterialsen_US
dc.subjectComputational Materials Scienceen_US
dc.subjectRadiationen_US
dc.titleGamma-ray-shielding parameters of some phantom fabrication materials for medical dosimetryen_US
dc.typeArticleen_US

Dosyalar

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: