USB-endoscope laryngoscope is as effective as video laryngoscope in difficult intubation

dc.contributor.authorGüngörer, Bülent
dc.contributor.authorFındık, Meliha
dc.contributor.authorKayıpmaz, Afşin Emre
dc.date.accessioned2022-10-18T08:14:48Z
dc.date.available2022-10-18T08:14:48Z
dc.date.issued2021en_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.descriptionFındık, Meliha (Balikesir Author)en_US
dc.description.abstractBackground: Video laryngoscopy (VL) has recently been put into clinical use to minimize the limitations of direct laryngoscopy and assist physicians interested in airway management. However, the high cost is the biggest constraint especially in countries with limited resources. To lower the cost, a custom-made VL obtained by attaching a USB-endoscope camera ($8.5) to the Macintosh laryngoscope (USB-L) can be used. Material and Methods: All intubations were performed in a difficult intubation model. Intubations were carried out by two emergency physicians. A Glidescope as a VL and a custom-made USB-L were used. In addition to these devices, one bougie to facilitate the advancement of the tube was used. The total intubation time was evaluated. Results: Correct tube placement for both operators was 100% for both devices. A difference between the operators in the duration of intubations could not be found. Also, there is no difference in the duration of intubations between the devices for both operators. Conclusion: It was concluded that the USB-L and VL are not statistically different in terms of intubation time in the difficult intubation model using bougie. For countries with limited resources, the low-cost USB-L has come to the forefront due to the high cost of VL and difficulty of access. © 2021 Via Medica.en_US
dc.identifier.doi10.5603/DEMJ.A2021.0012
dc.identifier.endpage79en_US
dc.identifier.issn2451-4691
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85110475809
dc.identifier.scopusqualityQ2
dc.identifier.startpage75en_US
dc.identifier.urihttps://doi.org/10.5603/DEMJ.A2021.0012
dc.identifier.urihttps://hdl.handle.net/20.500.12462/12609
dc.identifier.volume6en_US
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherVia Medicaen_US
dc.relation.ispartofDisaster and Emergency Medicine Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBougieen_US
dc.subjectDifficult Intubationen_US
dc.subjectIntubation Timeen_US
dc.subjectMannequinen_US
dc.subjectVideo Laryngoscopeen_US
dc.titleUSB-endoscope laryngoscope is as effective as video laryngoscope in difficult intubationen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
meliha-fındık2.pdf
Boyut:
269.87 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: