Seismic Performance of a Full-Scale FRP Retrofitted Sub-standard RC Building

dc.authoridDemir, Cem/0000-0001-8274-5361
dc.contributor.authorIlki, Alper
dc.contributor.authorTore, Erkan
dc.contributor.authorDemir, Cem
dc.contributor.authorComert, Mustafa
dc.date.accessioned2025-07-03T21:25:01Z
dc.date.issued2018
dc.departmentBalıkesir Üniversitesi
dc.description16th European Conference on Earthquake Engineering -- JUN, 2018 -- Thessaloniki, GREECE
dc.description.abstractExternal jacketing of columns with Fiber Reinforced Polymers (FRPs) is a promising retrofitting technique for improving seismic performance of sub-standard reinforced concrete (RC) buildings. The enhancement in deformation capacity and shear strength of jacketed members helps to prevent the brittle collapse mechanism of buildings with inadequate ductility. This paper provides an overview on the retrofitting of columns with FRP jacketing for particularly ductility enhancement and gives a brief summary of seismic strengthening recommendations of various design documents. In addition, a recent full-scale test conducted simultaneously on an as-built and a FRP retrofitted building, which are identical with design geometry, material quality and seismic deficiencies, is briefly presented and the performance of the retrofitting technique is evaluated. Finally, analytical behavior obtained through nonlinear static analyses executed using FRP-confined concrete models recommended in different technical documents are reviewed in comparison with the experimental behavior.
dc.description.sponsorshipEuropean Assoc Earthquake Engn,Hellen Soc Earthquake Engn
dc.identifier.doi10.1007/978-3-319-75741-4_22
dc.identifier.endpage544
dc.identifier.isbn978-3-319-75741-4
dc.identifier.isbn978-3-319-75740-7
dc.identifier.issn1573-6059
dc.identifier.issn1872-4671
dc.identifier.scopusqualityQ4
dc.identifier.startpage519
dc.identifier.urihttps://doi.org/10.1007/978-3-319-75741-4_22
dc.identifier.urihttps://hdl.handle.net/20.500.12462/21316
dc.identifier.volume46
dc.identifier.wosWOS:000546471200022
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofRecent Advances in Earthquake Engineering in Europe
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250703
dc.subjectFiber-Reinforced Polymer
dc.subjectStress-Strain Model
dc.subjectBond-Critical Regions
dc.subjectSurface-Mounted Frp
dc.subjectBeam-Column Joints
dc.subjectConcrete Columns
dc.subjectConfined Concrete
dc.subjectCompressive Behavior
dc.subjectInfill Walls
dc.subjectCfrp
dc.titleSeismic Performance of a Full-Scale FRP Retrofitted Sub-standard RC Building
dc.typeConference Object

Dosyalar