Double-J stent placement with grasping forceps through ureteroscope working channel: A novel technique

dc.authorid0000-0002-9780-9732en_US
dc.contributor.advisorKoç, Akif (Balikesir Author)en_US
dc.contributor.authorKoç, Akif
dc.contributor.authorBayrak, Ömer
dc.date.accessioned2019-11-22T10:08:15Z
dc.date.available2019-11-22T10:08:15Z
dc.date.issued2013en_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractAim: To report a new technique for the retrograde placement of a double-J stent with grasping forceps through the ureteroscope working channel. Materials and methods: In our technique, the ureteroscope is advanced to the renal pelvis or proximal location of the obstruction in the ureteral lumen; a double-J stent is then introduced into the ureteroscope working channel. The double-J stent is pushed forward until its proximal tip is seen; then the clamp over the distal tip of the pusher is opened and the guide-wire and pusher are removed from the channel, respectively. The grasping forceps is inserted into the working channel until it is touching the stent; the ureteroscope is removed from the ureter by pulling it over the stent and grasping forceps. Thus, the stent is placed in the ureteral lumen. Results: This technique was successful in 17 patients: 16 retrograde ureteroscopies for stone extraction and 1 retrograde ureteroscopy with ureteropelvic junction obstruction. No complications occurred during follow-up. Conclusion: Our simple technique may be safely used to place double-J stent in cases of ureteral obstruction. It may reduce procedure time and it avoids the potential complications of blind catheter placement.en_US
dc.identifier.doi10.3906/sag-1206-40
dc.identifier.endpage644en_US
dc.identifier.issn1300-0144
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-84880934942
dc.identifier.scopusqualityQ1
dc.identifier.startpage642en_US
dc.identifier.trdizinid150373
dc.identifier.urihttps://doi.org/10.3906/sag-1206-40
dc.identifier.urihttps://hdl.handle.net/20.500.12462/10053
dc.identifier.volume43en_US
dc.identifier.wosWOS:000323609800026
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoenen_US
dc.publisherTubitak Scientific & Technical Research Council Turkeyen_US
dc.relation.ispartofTurkish Journal of Medical Sciencesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectUrinary Catheterizationen_US
dc.subjectUreteroscopyen_US
dc.subjectStentsen_US
dc.subjectMethodsen_US
dc.subjectUreteren_US
dc.titleDouble-J stent placement with grasping forceps through ureteroscope working channel: A novel techniqueen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
akif-koç.pdf
Boyut:
404.62 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: