Corneal power changes and refractive outcomes of phacoemulsification cataract surgery in patients with pseudoexfoliation glaucoma and primary open angle glaucoma

dc.authorid0000-0002-7420-8934
dc.authorid0000-0003-2933-1623
dc.contributor.authorUzel, Mehmet Murat
dc.contributor.authorEraslan, Said Numan
dc.date.accessioned2026-03-04T07:06:59Z
dc.date.issued2024
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü
dc.descriptionUzel, Mehmet Murat (Balikesir Author)
dc.description.abstractPurpose: To compare the refractive deviations after phacoemulsification surgery in patients with pseudoexfoliation glaucoma (PEG) and primary open angle glaucoma (POAG) and to investigate the effect of anterior segment parameters on these deviations. Materials and Methods: Preoperative and postoperative 6th month values of spherical equivalents, axial lengths, anterior chamber depths, corneal powers of POAG and PEG patients who had undergone phacoemulsification surgery were compared retrospectively. Results: A total of 41 patients, 24 with PEG and 17 with POAG, were included in the study. There were no statistically significant differences between the groups in terms of axial length, preoperative intraocular pressure (IOP), 6-month postoperative IOP, IOP reduction, lens thickness, anterior chamber depth, surgically induced astigmatism, preoperative central corneal thickness (CCT), 6-month postoperative CCT, CCT thinning, 6-month postoperative spherical equivalent (SE), and deviation from the target refraction. There were no statistically significant differences in the measurements of anterior corneal power, posterior corneal power and net corneal power between the PEG and POAG groups preoperatively and at 6 months postoperatively. (p>0.05 for all). Conclusion: This study demonstrates that PEG and POAG patients undergoing cataract surgery have similar clinical outcomes, including anterior segment parameters and refractive outcomes.
dc.identifier.doi10.37844/TJ-CEO.2024.19.18
dc.identifier.endpage139
dc.identifier.issn3023-7505
dc.identifier.issue3
dc.identifier.scopus2-s2.0-105029560521
dc.identifier.startpage135
dc.identifier.trdizinid1328778
dc.identifier.urihttps://doi.org/10.37844/TJ-CEO.2024.19.18
dc.identifier.urihttps://hdl.handle.net/20.500.12462/23281
dc.identifier.volume19
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherGazi Eye Foundation
dc.relation.ispartofTurkish Journal of Clinical and Experimental Ophthalmology
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectPhacoemulsification
dc.subjectPrimary Open Angle Glaucoma
dc.subjectPseudoexfoliation Glaucoma
dc.subjectCorneal Power
dc.titleCorneal power changes and refractive outcomes of phacoemulsification cataract surgery in patients with pseudoexfoliation glaucoma and primary open angle glaucoma
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
mehmet-murat-uzel.pdf
Boyut:
283.82 KB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: