Erythrocyte autoantibody positivity in serological cross-matching

dc.contributor.authorAtik, Bülent
dc.contributor.authorAtik, Tuğba Kula
dc.contributor.authorDuran, Hülya
dc.contributor.authorBaykan, Özgür
dc.contributor.authorErsal, Tuba
dc.contributor.authorAvcı, Emine
dc.contributor.authorİspir, Emre
dc.contributor.authorBektöre, Bayhan
dc.date.accessioned2021-03-29T08:53:29Z
dc.date.available2021-03-29T08:53:29Z
dc.date.issued2020en_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractObjective: To investigate the erythrocyte autoantibody positivity detected in the serological cross-matching (XM), and its possible effects on salient hemogram parameters. Study Design: A descriptive study. Place and Duration of Study: Balikesir Ataturk City Hospital's Blood Transfusion Centre, Faculty of Medicine, Department of Anesthesiology and Reanimation, Balikesir University, Turkey, from 2017 to 2018. Methodology: Erythrocyte autoantibody positivity, which was detected in the traditional serological cross-matching for a pre-transfusion laboratory test were analysed retrospectively. Later, hemogram changes in the previous (no erythrocyte autoantibodies) and following (erythrocyte autoantibodies present) transfusions were investigated using statistical methods. Results: Erythrocyte autoantibody positivity rate was 10.16% (342/3,365). There was no statistically significant difference in the increase of hemoglobin, hematocrit, and red blood cell between the period when erythrocyte autoantibodies were detected or not, (p = 0.27, 0.13, and 0.09, respectively). Conclusion: Erythrocyte autoantibodies positivity found on routine cross-match exmination, which must be considered together with parameters such as previous transfusion history, other pre-transfusion laboratory test results, and clinical presentation and management.en_US
dc.identifier.doi10.29271/jcpsp.2020.5.485
dc.identifier.endpage489en_US
dc.identifier.issn1022-386X
dc.identifier.issn1681-7168
dc.identifier.issue5en_US
dc.identifier.scopus2-s2.0-85087099235
dc.identifier.scopusqualityQ2
dc.identifier.startpage485en_US
dc.identifier.urihttps://doi.org/10.29271/jcpsp.2020.5.485
dc.identifier.urihttps://hdl.handle.net/20.500.12462/11335
dc.identifier.volume30en_US
dc.identifier.wosWOS:000543463300007
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherColl Physicians & Surgeons Pakistanen_US
dc.relation.ispartofJournal of the College of Physicians and Surgeons Pakistanen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectTransfusionen_US
dc.subjectErythrocye Autoantibodyen_US
dc.subjectAlloantibodyen_US
dc.subjectHemogramen_US
dc.subjectCross-matchingen_US
dc.titleErythrocyte autoantibody positivity in serological cross-matchingen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
bulen-atik3.pdf
Boyut:
160.14 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: