Performance evaluations of a geothermal power plant

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Pergamon-Elsevier Science Ltd

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Thermodynamic analysis of an operational 7.5 MWe binary geothermal power plant in Tuzla-Turkey is performed, through energy and exergy, using actual plant data to assess its energetic and exergetic performances. Eight performance-related parameters, namely total exergy destruction ratio, component exergy destruction ratio, dimensionless exergy destruction, energetic renewability ratio, exergetic renewability ratio, energetic reinjection ratio, exergetic reinjection ratio and improvement potential are investigated. Energy and exergy losses/destructions for the plant and its units are determined and illustrated using energy and exergy flow diagrams. The largest energy and exergy losses occur in brine reinjection unit. The variation of the plant energy efficiency is found between 6% and 12%. Exergy efficiency values change between 35 and 49%. The annual average energy and exergy efficiencies are found as 9.47% and 45.2%, respectively.

Açıklama

Coşkun, Can (Balıkesir Author)

Anahtar Kelimeler

Geothermal Energy, Exergy, Efficiency, Geothermal Power Plant, Binary Plant, Performance Parameters

Kaynak

Applied Thermal Engineering

WoS Q Değeri

Scopus Q Değeri

Cilt

31

Sayı

17-18

Künye

Onay

İnceleme

Ekleyen

Referans Veren