Reliability and validity of the Turkish version of Function in Sitting Test (FIST-T) in stroke

dc.authorid0000-0002-8680-1081en_US
dc.authorid0000-0002-8786-7496en_US
dc.authorid0000-0001-5470-9849en_US
dc.contributor.authorErol, Büşra Nur
dc.contributor.authorAydoğan, Saniye Arslan
dc.contributor.authorYaşar, Evren
dc.contributor.authorKeskin, Esra Dilek
dc.contributor.authorDemirci, Cevher Savcun
dc.date.accessioned2022-08-04T07:40:22Z
dc.date.available2022-08-04T07:40:22Z
dc.date.issued2021en_US
dc.departmentFakülteler, Sağlık Bilimleri Fakültesi, Fizyoterapi ve Rehabilitasyon Bölümüen_US
dc.descriptionDemirci, Cevher Savcun (Balikesir Author)en_US
dc.description.abstractBackground: Trunk control in sitting position after stroke is one of the most important determinants of independence in daily living activities and there is no gold standard assessment used to measure sitting postural control. Objectives: The aim of this study is to determine the reliability and validity of the Turkish version of Function in Sitting Test (FIST-T). Methods: After translation was conducted, Function in Sitting Test, Berg Balance Scale, Functional Independent Measure and Trunk Impairment Scale were applied to 72 stroke patients (mean age was 59.26 +/- 16.38 years; post-stroke time was 95.93 +/- 59.64 days). For reliability and validity analysis the spearman correlation analysis was used. Results: A positive, high correlation was found between the first application and repetition of Function in Sitting Test-T (ICC = 0.97, r = 0.95, p = .001). The internal consistency was high (Cronbach Alpha = 0.97), interrater correlation was high (Cronbach Alpha = 0.98) and a positive, high correlation was found with the scores obtained from the Berg Balance Scale (r = 0.82, p = .001), Functional Independent Measure (r = 0.84, p = .001) and Trunk Impairment Scale (r = 0.80, p = .001). Conclusions: It is concluded that the Turkish version of Function in Sitting Test is a valid and reliable scale for use in stroke patients, in clinical and scientific researches.en_US
dc.identifier.doi10.1080/10749357.2020.1871284
dc.identifier.endpage57en_US
dc.identifier.issn1074-9357
dc.identifier.issn1945-5119
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85099418741
dc.identifier.scopusqualityQ1
dc.identifier.startpage49en_US
dc.identifier.urihttps://doi.org/10.1080/10749357.2020.1871284
dc.identifier.urihttps://hdl.handle.net/20.500.12462/12416
dc.identifier.volume29en_US
dc.identifier.wosWOS:000607442500001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherTaylor & Francis Ltden_US
dc.relation.ispartofTopics in Stroke Rehabilitationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectFunction in Sitting Testen_US
dc.subjectStrokeen_US
dc.subjectReliabilityen_US
dc.subjectValidityen_US
dc.subjectSitting Balanceen_US
dc.titleReliability and validity of the Turkish version of Function in Sitting Test (FIST-T) in strokeen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
cevher-savcun-demirci6.pdf
Boyut:
2.45 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: