Flow injection determination of aluminium by spectrofluorimetric detection after complexation with N-o-vanillidine-2-amino-p-cresol: The application to natural waters

dc.authorid0000-0003-4373-4904en_US
dc.contributor.authorKara, Derya
dc.contributor.authorFisher, Andrew
dc.contributor.authorHill, Steve J.
dc.date.accessioned2019-10-17T11:05:13Z
dc.date.available2019-10-17T11:05:13Z
dc.date.issued2008en_US
dc.departmentFakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümüen_US
dc.descriptionKara, Derya (Balikesir Author)en_US
dc.description.abstractAn on-line flow injection spectrofluorimetric method for the direct determination of aluminium in water samples is described. The method is based on the reaction of aluminium with N-o-vanillidine-2-amino-p-cresol (OVAC) in acidic medium at pH 4.0 to form a watersoluble complex. The excitation and emission wavelengths were 423.0 and 553.0 nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% methanol-50% water medium at 50 degrees C. An interference from fluoride ions was minimised by the addition of Be2+. Other ions were found not to interfere at the concentrations likely to be found in natural waters. The proposed methods were validated in terms of linearity, repeatability detection limit, accuracy and selectivity. Under these conditions, the calibration was linear up to 1000 mu g L-1 (r=0.999). The limit of detection (3 sigma) for the determination of Al(III) was 0.057 mu g L-1 and the precision for multiple determinations of 3 ng mL(-1) Al(III) prepared in ultra-pure water was found to be 0.62% (n=10). The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both fresh-water and saline solutions, including seawater.en_US
dc.identifier.doi10.1016/j.aca.2008.01.044
dc.identifier.endpage67en_US
dc.identifier.issn0003-2670
dc.identifier.issn1873-4324
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-39549099300
dc.identifier.scopusqualityQ1
dc.identifier.startpage62en_US
dc.identifier.urihttps://doi.org/ 10.1016/j.aca.2008.01.044
dc.identifier.urihttps://hdl.handle.net/20.500.12462/8416
dc.identifier.volume611en_US
dc.identifier.wosWOS:000254776300007
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofAnalytica Chimica Actaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFlow Injectionen_US
dc.subjectAluminium Determinationen_US
dc.subjectN-O-Vanillidine-2-Amino-P-Cresolen_US
dc.subjectSpectrofluorimetryen_US
dc.subjectSeawateren_US
dc.subjectRiver Wateren_US
dc.titleFlow injection determination of aluminium by spectrofluorimetric detection after complexation with N-o-vanillidine-2-amino-p-cresol: The application to natural watersen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
derya-kara2.pdf
Boyut:
269.26 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: