Low anterior chamber volume as a risk factor in non-arteritic anterior ischemic optic neuropathy

dc.contributor.authorAcan, Durgul
dc.contributor.authorCakar, Beyza Betul
dc.contributor.authorKarahan, Eyyup
dc.date.accessioned2025-07-03T21:25:21Z
dc.date.issued2025
dc.departmentBalıkesir Üniversitesi
dc.description.abstractPurpose This study aimed to compare the anterior chamber depth (ACD), anterior chamber volume (ACV), and iridocorneal angle (ICA) of the eyes of patients with non-arteritic anterior ischemic optic neuropathy (NAION) and normal eyes. Methods In this cross-sectional study, 28 patients with NAION who were admitted to our institution were examined. Central corneal thickness (CCT), ACV, ACD, and ICA of all eyes were measured using corneal topography (Sirius, CSO, Italy). Axial lengths (ALs) were measured using an IOL-Master 500 (Carl Zeiss, Meditec). The eyes of these patients were compared with the eyes of 29 healthy individuals of similar age and gender. Results The mean ALs of the eyes with NAION and those in the control group were not statistically different, measuring 22.95 +/- 0.68 mm and 23.13 +/- 0.80mm, respectively (p=0.651). While the average ACV was 137.93 +/- 41.01 mm3 in the control group, it was significantly lower at 117.86 +/- 22.23 mm3 in the patients with NAION (p=0.038). The mean ACD, ICA, and CCT values in the control and study groups were not statistically different, with 2.82 +/- 0.57 mm and 2.64 +/- 0.31 mm, 41.62 +/- 6.99 degrees and 40.14 +/- 7.04 degrees, and 542.48 +/- 19.39 mu m and 544.68 +/- 31.26 mu m, respectively (p1 = 0.236, p2 = 0.693, and p3 = 0.959). No statistical differences were found between the eyes with NAION and their fellow eyes in terms of AL, CCT, ACD, ACV, and ICA (p>0.05). Conclusion Differences in anterior segment morphology were observed in eyes with NAION compared to healthy eyes. Decreased ACV may be a risk factor for NAION.
dc.identifier.doi10.3389/fopht.2025.1554279
dc.identifier.issn2674-0826
dc.identifier.pmid40462869
dc.identifier.scopus2-s2.0-105007143706
dc.identifier.scopusqualityQ4
dc.identifier.urihttps://doi.org/10.3389/fopht.2025.1554279
dc.identifier.urihttps://hdl.handle.net/20.500.12462/21481
dc.identifier.volume5
dc.identifier.wosWOS:001500470700001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherFrontiers Media Sa
dc.relation.ispartofFrontiers in Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250703
dc.subjectanterior chamber depth
dc.subjectanterior chamber volume
dc.subjectcentral corneal thickness
dc.subjectiridocorneal angle
dc.subjectnonarteritic anterior ischemic optic neuropathy
dc.titleLow anterior chamber volume as a risk factor in non-arteritic anterior ischemic optic neuropathy
dc.typeArticle

Dosyalar