Influence of draft tube cross-sectional geometry on K(L)a and epsilon in jet loop bioreactors (JLB)

dc.contributor.authorFarizoğlu, Burhanettin
dc.contributor.authorKeskinler, Bülent
dc.date.accessioned2019-10-17T10:40:51Z
dc.date.available2019-10-17T10:40:51Z
dc.date.issued2007en_US
dc.departmentFakülteler, Mühendislik Fakültesi, Çevre Mühendisliği Bölümüen_US
dc.descriptionFarizoğlu, Burhanettin (Balikesir Author)en_US
dc.description.abstractDue to their compactness, and high flexibility in operation, the new processes like jet loop bioreactors (JLB) show a large potential for high removal efficiency and significant cost reduction in particular for the biological treatment of highly polluted wastewater. The rate of oxygen delivery determines the efficiency of aerobic processes. A modified JLB with square cross-sectional draft tube was developed in this study. Experiments were performed to investigate the effects of cross-sectional geometry, liquid flow rate and gas flow rate on gas hold-up and KLa. The comparison of these parameters as well as KI.a was carried out for two cross-sectional draft tubes geometry. The results indicated that KI.a values were better by 11-13% in square draft tube. In this study, the mass transfer characteristics with the square draft tube configuration have also been studied and a model was developed for this configuration.en_US
dc.identifier.doi10.1016/j.cej.2007.02.022
dc.identifier.endpage299en_US
dc.identifier.issn1385-8947
dc.identifier.issue1-3en_US
dc.identifier.scopus2-s2.0-34250657991
dc.identifier.scopusqualityQ1
dc.identifier.startpage293en_US
dc.identifier.urihttps://doi.org/10.1016/j.cej.2007.02.022
dc.identifier.urihttps://hdl.handle.net/20.500.12462/8228
dc.identifier.volume133en_US
dc.identifier.wosWOS:000248174600031
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherElsevier Science Saen_US
dc.relation.ispartofChemical Engineering Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectJet Loop Reactorsen_US
dc.subjectDraft Tubesen_US
dc.subjectBioreactorsen_US
dc.subjectGas-Liquid Mass Transferen_US
dc.subjectGas Hold-Upen_US
dc.titleInfluence of draft tube cross-sectional geometry on K(L)a and epsilon in jet loop bioreactors (JLB)en_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
burhanettin-farizoglu.pdf
Boyut:
838.47 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin /Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: