On-line solid phase extraction of nickel, copper, and cadmium using a newly synthesized polyamine silica gel-loaded mini-column for flame atomic absorption spectrometric determination

dc.authorid0000-0002-9521-1024en_US
dc.contributor.authorSivrikaya, Sezen
dc.contributor.authorİmamoğlu, Mustafa
dc.contributor.authorKara, Derya
dc.date.accessioned2019-10-17T10:31:16Z
dc.date.available2019-10-17T10:31:16Z
dc.date.issued2014en_US
dc.departmentFakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümüen_US
dc.descriptionFisher, Kara Derya (Balıkesir Author)en_US
dc.description.abstractIn this study, polyamine (pentaethylene hexamine) functionalized silica gel (PA-SG) was prepared as a novel sorbent material for on-line preconcentration of Cd(II), Cu(II), and Ni(II) from complex matrices. The PA-SG was characterized by means of elemental analysis and FT-IR spectroscopic techniques. The effective parameters for on-line preconcentration and separation of Cd(II), Cu(II), Ni(II), and FAAS detection were optimized by investigating the effects of sample pH, type, and concentration of eluent, flow rate of sample and eluent, loop volume, and matrix ions. The linear range of the proposed method was between10-200 mu g L-1 for each element, with enrichment factors of 39.9, 30.4, and 43.6 and detection limits of 0.19, 0.73, and 0.91 mu g L-1 for Cd(II), Cu(II), and Ni(II), respectively, by loading 5.0 mL of sample solution. The precision of the method (evaluated as the relative standard deviation obtained after analyzing 11 samples with three replicates each) was determined as 3.2, 2.4, and 4.0% for 20 mu g L-1 of Cd(II), 0.1 mg L-1 of Cu(II) and Ni(II), respectively, by loading 5.0 mL of sample solution. The sorption capacities of PA-SG were 41.4, 33.1, and 23.7 mg for Cd(II), Cu(Il), and Ni(II) per gram of resin, respectively. The accuracy of the proposed on-line precortcentration procedure was evaluated by analyzing reference materials CTA-VTL-2 Virginia Tobacco Leaves and NWTM-15.2 Water - Trace Elements. Application of the proposed procedure was successfully accomplished for the analysis of natural water and food samples.en_US
dc.description.sponsorshipSakarya University Research Fund 2012-50-02-036en_US
dc.identifier.endpage176en_US
dc.identifier.issn0195-5373
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84906886686
dc.identifier.scopusqualityQ2
dc.identifier.startpage168en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12462/8115
dc.identifier.volume35en_US
dc.identifier.wosWOS:000340513100005
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.language.isoenen_US
dc.publisherPerkin-Elmer Corpen_US
dc.relation.ispartofAtomic Spectroscopyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleOn-line solid phase extraction of nickel, copper, and cadmium using a newly synthesized polyamine silica gel-loaded mini-column for flame atomic absorption spectrometric determinationen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
derya-kara-5.pdf
Boyut:
277.96 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: