Conformable fractional order controller design and implementation for per-phase voltage regulation of three-phase SEIG under unbalanced load

dc.authorid0000-0002-9608-2148en_US
dc.contributor.authorİlten, Erdem
dc.date.accessioned2023-07-21T07:40:24Z
dc.date.available2023-07-21T07:40:24Z
dc.date.issued2022en_US
dc.departmentFakülteler, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.description.abstractSelf-excited induction generators (SEIGs) usage is an effective way to generate electrical power in off-grid locations. This study aims to performance improvement for voltage regulation of the SEIG in wind turbine systems. To achieve this, a fixed-capacitor with thyristor controlled-reactor based per-phase voltage controller is designed with a conformable fractional order proportional integral (CFOPI) method. The SEIG system is modeled based on small signal analysis by using the input-output data, experimentally. To do this, system identification toolbox of Matlab is used. The proposed controller is established on conformable fractional integral approach proposed by Khalil et al. in 2014. Proposed CFOPI controller parameters Kp, Ki and c are optimized using particle swarm optimization (PSO) according to minimization of integral time absolute error (ITAE). To validate the success of proposed scheme, CFOPI, traditional fractional order PI (TFOPI) and integer order PI (IOPI) controllers are tested under same experimental setup and results are compared. Three experiments, after voltage build-up process, under balanced and unbalanced load are done for each controller. Experimental results demonstrate that proposed voltage regulator improves the performance of SEIG systems. Moreover, robust voltage regulation is ensured thanks to independent control loops created for each phase.en_US
dc.identifier.doi10.1080/15325008.2022.2139433
dc.identifier.endpage648en_US
dc.identifier.issn1532-5008
dc.identifier.issn1532-5016
dc.identifier.issue11-12en_US
dc.identifier.scopus2-s2.0-85141359146
dc.identifier.scopusqualityQ3
dc.identifier.startpage636en_US
dc.identifier.urihttps://doi.org/10.1080/15325008.2022.2139433
dc.identifier.urihttps://hdl.handle.net/20.500.12462/13240
dc.identifier.volume50en_US
dc.identifier.wosWOS:000878063000001
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherTaylor & Francis Incen_US
dc.relation.ispartofElectric Power Components and Systemsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectSEIGen_US
dc.subjectFC-TCRen_US
dc.subjectVoltage Regulationen_US
dc.subjectConformable Fractional Order Controlen_US
dc.titleConformable fractional order controller design and implementation for per-phase voltage regulation of three-phase SEIG under unbalanced loaden_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
erdem-ilten3.pdf
Boyut:
2.39 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: