Preconcentration of heavy metals and matrix elimination using silica gel chemically modified with 2,3-dihydroxybenzaldehyde

dc.authorid0000-0003-4373-4904en_US
dc.contributor.authorAlan, Mesut
dc.contributor.authorKara, Derya
dc.contributor.authorFisher, Andrew
dc.date.accessioned2019-10-17T08:23:52Z
dc.date.available2019-10-17T08:23:52Z
dc.date.issued2007en_US
dc.departmentFakülteler, Fen-Edebiyat Fakültesi, Kimya Bölümüen_US
dc.descriptionKara, Derya (Balikesir Author)en_US
dc.description.abstractMany direct methods cannot easily be used to measure analytes such as Cd(II), Cu(II), Ni(II), Pb(II), and Zn(II) ions in sea and river water since these elements are present at very low concentration and the sample has a very complex matrix. In this study a method was developed to preconcentrate these ions by solid phase extraction within a column system using a newly synthesised 2,3-dihydroxy benzaldehyde modified silica gel (SGDHB). Different parameters, such as pH, resin amount, eluent type, eluent volume, sample flow rate, preconcentration factors, and resin capacity were determined for the preconcentration of metal ions with the resin. Samples (125-500 ml) containing metal ions were passed through the column filled with SGDHB resin so that metal ions were retained on the column. The preconcentrated analytes were then eluted with 15 mL of 0.1 M HCl. The metal concentrations in the eluate were measured by FAAS. A sample and eluent flow rate of 1.12 and 0.56 ml/min respectively was used. Estimates of accuracy, precision, and detection limits were determined. In addition, analysis of the CRM LGC 6156 harbor sediment was undertaken, using the resin to isolate the analytes from potential interferences. Good agreement with certified values was obtained, indicating that the method is equally applicable to the analysis of water samples and to digests of solid materials.en_US
dc.identifier.doi10.1080/01496390601174182
dc.identifier.endpage895en_US
dc.identifier.issn0149-6395
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-33947374238
dc.identifier.scopusqualityQ2
dc.identifier.startpage879en_US
dc.identifier.urihttps://doi.org/10.1080/01496390601174182
dc.identifier.urihttps://hdl.handle.net/20.500.12462/7975
dc.identifier.volume42en_US
dc.identifier.wosWOS:000245356300012
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherTaylor & Francis Incen_US
dc.relation.ispartofSeparation Science and Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectSolid Phase Extractionen_US
dc.subjectCd(II)en_US
dc.subjectCu(II)en_US
dc.subjectNi(II)en_US
dc.subjectPb(II) And Zn(II) Preconcentrationen_US
dc.subjectModified Silica Gelen_US
dc.subjectFAASen_US
dc.titlePreconcentration of heavy metals and matrix elimination using silica gel chemically modified with 2,3-dihydroxybenzaldehydeen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
mesut-alan.pdf
Boyut:
369.38 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: