Calculation of insulation thickness depending on the coolest and hottest climate conditions for different flat roof types of buildings

dc.contributor.authorKon, Okan
dc.contributor.authorCaner, İsmail
dc.date.accessioned2024-02-05T15:58:35Z
dc.date.available2024-02-05T15:58:35Z
dc.date.issued2023
dc.departmentFakülteler, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.description.abstractIn this study, optimum insulation thicknesses are calculated for three different flat-surfaces which are navigable terrace roof; stone-covered and soil-covered un-navigable flat roof types. The outdoor temperature, the value of January, which is the coldest month in winter, and the value of July, which is the hottest month in summer, and solar radiation, are considered together. Flat roof surfaces are considered to be stone-covered and soil-covered black painted and marble. Firstly, solar-air temperatures were determined for the winter and summer periods. Then, optimum insulation thickness calculations are made using life cycle total cost analysis. Extruded polystyrene (XPS) is accepted as the insulation material. Natural gas is used in winter and electricity in summer as an energy sources. The optimum insulation thicknesses have been calculated for five climate zones and three different roof types based on the TS 825. Then the results are compared. As a result, the optimum insulation thickness calculated considering the hottest and coldest months of the year was determined as 0.128 m in the 5th climate zone in roof one with the highest value, and as the lowest value with the 0.052 m in the 1st climate zone for roof three.en_US
dc.identifier.doi10.34248/bsengineering.1125983
dc.identifier.endpage9en_US
dc.identifier.issn2619-8991
dc.identifier.issue1en_US
dc.identifier.startpage1en_US
dc.identifier.trdizinid1153506
dc.identifier.urihttps://doi.org/10.34248/bsengineering.1125983
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1153506
dc.identifier.urihttps://hdl.handle.net/20.500.12462/14144
dc.identifier.volume6en_US
dc.indekslendigikaynakTR-Dizin
dc.language.isoenen_US
dc.relation.ispartofBlack Sea Journal of Engineering and Scienceen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/*
dc.snmztrdizinidealen_US]
dc.subjectFlat Roofen_US
dc.subjectGreen Roofen_US
dc.subjectOptimum Insulation Thicknessen_US
dc.subjectSolar-Air Temperatureen_US
dc.subjectTS 825 Standarden_US
dc.titleCalculation of insulation thickness depending on the coolest and hottest climate conditions for different flat roof types of buildingsen_US