Determination of optimum insulation thicknesses using economical analyse for exterior walls of buildings with different masses

Yükleniyor...
Küçük Resim

Tarih

Yazarlar

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

In this study, five different cities were selected from the five climatic zones according to Turkish standard TS 825, and insulation thicknesses of exterior walls of sample buildings were calculated by using optimization. Vertical perforated bricks with density of 550 kg/m3 and 1000 kg/m3werechosen within the study content. Glass wool, expanded polystyrene (XPS), extruded polystyrene (EPS) were considered as insulation materials. Additionally, natural gas, coal, fuel oil and LPG were utilized as fuel for heating process while electricity was used for cooling. Life cycle cost (LCC) analysis and degree-day method were the approaches for optimum insulation thickness calculations. As a result, in case of usage vertical perforated bricks with density of 550 kg/m3 and 1000 kg/m3 resulted different values in between 0.005-0.007 m (5-7 mm) in the optimum insulation thickness calculations under different insulation materials. Minimum optimum insulation thickness was calculated in case XPS was preferred as insulation material, and the maximum one was calculated in case of using glass wool.

In this study, five different cities were selected from the five climatic zones according to Turkish standard TS 825, and insulation thicknesses of exterior walls of sample buildings were calculated by using optimization. Vertical perforated bricks with density of 550 kg/m3 and 1000 kg/m3werechosen within the study content. Glass wool, expanded polystyrene (XPS), extruded polystyrene (EPS) were considered as insulation materials. Additionally, natural gas, coal, fuel oil and LPG were utilized as fuel for heating process while electricity was used for cooling. Life cycle cost (LCC) analysis and degree-day method were the approaches for optimum insulation thickness calculations. As a result, in case of usage vertical perforated bricks with density of 550 kg/m3 and 1000 kg/m3 resulted different values in between 0.005-0.007 m (5-7 mm) in the optimum insulation thickness calculations under different insulation materials. Minimum optimum insulation thickness was calculated in case XPS was preferred as insulation material, and the maximum one was calculated in case of using glass wool.

Açıklama

Anahtar Kelimeler

İstatistik ve Olasılık, Matematik, Uygulamalı, Matematik, Building Mass, Optimization, Thermal İnsulation, Lifecycle Cost Analysis, Degree-Day Method

Kaynak

An International Journal of Optimization and Control: Theories & Applications (IJOCTA)