The effect on video laryngoscope on intubation process during ambulance transport

dc.authorid0000-0002-4164-393Xen_US
dc.authorid0000-0003-0654-8061en_US
dc.contributor.authorÇağlar, Bahadır
dc.contributor.authorSerin, Süha
dc.date.accessioned2021-03-30T13:16:44Z
dc.date.available2021-03-30T13:16:44Z
dc.date.issued2020en_US
dc.departmentFakülteler, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractObjective: To compare the effects of VL and DL on intubation time and ease of operation in an ambulance, which is moving in real urban traffic. Design: Comparative experimental manikin study. Place and Duration of Study: Urla City Hospital, Izmir, Turkey, from January to May 2019. Methodology: The paramedics were asked to intubate a standard intubation manikin and manikin with cervical collar with DL and VL in an ambulance that moving in real urban traffic. Intubation time, incisor tooth injury, and the ease of operation data were recorded. Results: There was a statistically significant difference between the median values of DL and VL intubation times DL:18s/VL:15s in standard manikin and DL:28 s/VL:21 s in manikin with cervical collar (p<0.001). When the ease of operation was evaluated, the median scores of the DL and VL Likert 5 scale were determined in the standard manikin as DL:3/VL:5 and the manikin with collar as DL:2/VL:4 Conclusion: VL significantly decreased the intubation time compared to DL in both normal and difficult airways. The ease of operation provided by VL reduces the negative environmental factors brought by the out-of-hospital environment and ambulance movement for healthcare workers. The use of VL in limited conditions and time, reduces the intubation time and increases the ease of operation compared to DL.en_US
dc.identifier.doi10.29271/jcpsp.2020.4.351
dc.identifier.endpage354en_US
dc.identifier.issn1022-386X
dc.identifier.issn1681-7168
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85086242462
dc.identifier.scopusqualityQ2
dc.identifier.startpage351en_US
dc.identifier.urihttps://doi.org/10.29271/jcpsp.2020.4.351
dc.identifier.urihttps://hdl.handle.net/20.500.12462/11351
dc.identifier.volume30en_US
dc.identifier.wosWOS:000538941700002
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherColl Physicians & Surgeons Pakistanen_US
dc.relation.ispartofJCPSP-Journal of the College of Physicians and Surgeons Pakistanen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectResuscitationen_US
dc.subjectVideo Laryngoscopeen_US
dc.subjectTransporten_US
dc.titleThe effect on video laryngoscope on intubation process during ambulance transporten_US
dc.typeArticleen_US

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
bahadır-caglar2.pdf
Boyut:
222.1 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: