Comparison of Treatment Efficiency and Energy Consumption of Batch and Continuous Electrocoagulation in Urban Wastewater

Yükleniyor...
Küçük Resim

Tarih

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Wiley

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this study, domestic wastewater was used as the electrolyte. The work was carried out with an up-flow tubular reactor, made of stainless steel that was used as cathode, while the anode electrode material was aluminum and varying values of flow regime (25, 50, 75 and 100 mL/s for continuous system), initial pH value (5, 6, 7 and 7.8) and current intensity (10, 15 and 20 A) were applied. For domestic wastewater with natural pH, the effluent pH was >9 in the batch system, while in the continuous system the pH was 8-8.5. Likewise, while the effluent temperature was up to 60 degrees C in the batch system, it was at most 35 degrees C in the continuous system. However, the energy consumption values in the continuous system were considerably lower compared with the batch system. At a current intensity of 10 A, 80 kWh of energy per unit volume was consumed in the batch system, while it was 50 kWh for the continuous system. The present results show that the batch system can be used for small wastewater streams whereas the continuous system can be used for large wastewater streams for domestic wastewater treatment.

Açıklama

Anahtar Kelimeler

circulation and flow rate, COD removal, current intensity, electrocoagulation, pH

Kaynak

Clean-Soil Air Water

WoS Q Değeri

Scopus Q Değeri

Cilt

51

Sayı

1

Künye

Onay

İnceleme

Ekleyen

Referans Veren