Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKara, Derya
dc.contributor.authorFisher, Andrew S.
dc.contributor.authorHill, Steve J.
dc.date.accessioned2019-11-13T07:53:50Z
dc.date.available2019-11-13T07:53:50Z
dc.date.issued2007en_US
dc.identifier.issn1464-0325
dc.identifier.urihttps://hdl.handle.net/20.500.12462/9716
dc.identifier.urihttps://doi.org/10.1039/b708888ben_US
dc.descriptionKara, Derya (Balikesir Author)en_US
dc.description.abstractA simple, easy to use and selective spectrofluorimetric method for the determination of trace levels of aluminium has been developed. A new Schiff base, N-o-vanillidine-2-amino-p-cresol (OVAC), has been synthesized and its fluorescence activity with aluminium investigated. Based on this chelation reaction, a spectrofluorimetric method has been developed for the determination of aluminium in samples buffered at pH 4.0 using acetic acid-sodium acetate. The chelation reaction between Al(iii) and N-o-vanillidine-2-amino-p-cresol was very fast, requiring only 20 min at room temperature to complex completely. The excitation and emission wavelengths were 423.0 and 553.0 nm, respectively, at which the OVAC-Al complex gave the maximum fluorescence intensity at pH 4.0 in a 50% ethanol-50% water medium. The interference from fluoride ions was minimized by the addition of Be2+. Other ions were found not to interfere at the concentrations likely to be found in natural waters. Under these conditions, the calibration plot was linear up to 1000 μg L-1 (r = 0.999). The limit of detection (3σ) for the determination of Al(iii) was 0.19 μg L-1 and the precision for multiple determinations of 3 ng mL-1 Al(iii) prepared in ultra-pure water was found to be 0.29% (n = 16). The Schiff base ligand could be used to determine ultra-trace aluminium from natural waters. Analysis of environmental certified reference materials showed good agreement with the certified values. The procedure was found to be equally applicable to both fresh water and saline solutions (including sea water) using either normal external calibration or the standard additions method.en_US
dc.language.isoengen_US
dc.publisherRoyal Society of Chemistryen_US
dc.relation.isversionof10.1039/b708888ben_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAluminumen_US
dc.subjectAtomic Absorption Spectrometryen_US
dc.subjectSpectrophotometryen_US
dc.titleThe sensitive and selective determination of aluminium by spectrofluorimetric detection after complexation with N-o-vanillidine-2-amino-p- cresolen_US
dc.typeconferenceObjecten_US
dc.relation.journalJournal of Environmental Monitoringen_US
dc.contributor.departmentFen Edebiyat Fakültesien_US
dc.identifier.volume9en_US
dc.identifier.issue9en_US
dc.identifier.startpage994en_US
dc.identifier.endpage1000en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster