dc.description.abstractThe magnetic flux leakage (MFL) technique is most commonly used for crack detection from iron bars, laminated sheets, and steel tubes of ferromagnetic nature. Magnetic flux leakage system induces a magnetic field and detects magnetic flux lines that "leak" or change because of a discontinuity in the magnetized area. An inductive coil sensor or a Hall effect sensor detects the leakage. Magnetic methods of nondestructive testing (NDT) depend on detecting this magnetic flux leakage field. The ferromagnetic specimen is magnetized by suitable methods, and flaws which break the surface or just the subsurface distort the magnetic field, causing local flux leakage fields. It is very important for industrial applications to detect cracks and flaws in metal parts of the steel bridges, power stations, military tools and structures, and so forth. In this study, the inspection of cracks in laminated sheets under longitudinal magnetization will be discussed in detail.en_US
dc.language.isoengen_US
dc.relation.isversionof10.1155/2013/708396en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMagnetic Fluxen_US
dc.subjectMagnetic Leakageen_US
dc.subjectLeakage Testingen_US
dc.titleInvestigation of BX and by components of the magnetic flux leakage in ferromagnetic laminated sampleen_US
dc.typearticleen_US
dc.relation.journalAdvances in Materials Science and Engineeringen_US
dc.contributor.departmentFen Edebiyat Fakültesien_US
dc.identifier.volume2013en_US
dc.identifier.startpage1en_US
dc.identifier.endpage9en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster