Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorOktay, Zuhal
dc.contributor.authorDinçer, İbrahim
dc.date.accessioned2019-10-21T08:01:44Z
dc.date.available2019-10-21T08:01:44Z
dc.date.issued2009en_US
dc.identifier.issn0378-7788
dc.identifier.issn1872-6178
dc.identifier.urihttps://doi.org/10.1016/j.enbuild.2008.08.003
dc.identifier.urihttps://hdl.handle.net/20.500.12462/9062
dc.descriptionOktay, Zuhal (Balikesir Author)en_US
dc.description.abstractThis paper presents an application of an exergoeconomic model, through exergy and cost accounting analyses, to the Gonen geothermal district heating system (GDHS) in Balikesir, Turkey for the entire system and its components. This exergoeconomic model is used to reveal the cost formation process and the productive interaction between components. The exergy destructions in the overall Gonen GDHS are quantified and illustrated for a reference temperature of 4 degrees C. The results indicate that the exergy destructions in the system occur primarily as a result of losses in the cooled geothermal water injected back into the reservoir, pumps, heat exchangers, and pipelines. Total exergy destruction and reinjection exergy of the cooled geothermal water result in 1010 kW (accounting for 32.49%),320.3 kW (accounting for 10%) of the total exergy input to the Gonen GDHS, respectively. Both energy and exergy efficiencies of the overall Gonen GDHS are also investigated to analyze the system performance, as these efficiencies are determined to be 42% and 50%, respectively. It is found that an increase of the load condition leads to a decrease in the overall thermal costs, which will result in more cost-effective energy systems for buildings. (c) 2008 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipBalikesir University Natural Sciences and Engineering Research Council of Canadaen_US
dc.language.isoengen_US
dc.publisherElsevier Science Saen_US
dc.relation.isversionof10.1016/j.enbuild.2008.08.003en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGeothermal Energyen_US
dc.subjectGeothermal District Heatingen_US
dc.subjectEnergyen_US
dc.subjectExergyen_US
dc.subjectExergoeconomicsen_US
dc.titleExergoeconomic analysis of the Gonen geothermal district heating system for buildingsen_US
dc.typearticleen_US
dc.relation.journalEnergy and Buildingsen_US
dc.contributor.departmentMühendislik Mimarlık Fakültesien_US
dc.contributor.authorID0000-0001-6167-7048en_US
dc.identifier.volume41en_US
dc.identifier.issue2en_US
dc.identifier.startpage154en_US
dc.identifier.endpage163en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US