dc.description.abstractArsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm(2), stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m(3). Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 mu g/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m(3).en_US
dc.description.sponsorshipAtaturk University Scientific Research Project Department 2009/55en_US
dc.language.isoengen_US
dc.publisherBiomed Central Ltden_US
dc.relation.isversionof10.1186/2052-336X-12-95en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectArsenic Removalen_US
dc.subjectElectrocoagulationen_US
dc.subjectWastewater Treatmenten_US
dc.subjectİron Electrodeen_US
dc.titleEffect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodesen_US
dc.typearticleen_US
dc.relation.journalJournal of Environmental Health Science and Engineerıngen_US
dc.contributor.departmentMühendislik Fakültesien_US
dc.identifier.volume12en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster