Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAleem, Shady H. E. Abdel
dc.contributor.authorBalcı, Murat Erhan
dc.contributor.authorSakar, Selçuk
dc.date.accessioned2019-10-17T07:09:56Z
dc.date.available2019-10-17T07:09:56Z
dc.date.issued2015en_US
dc.identifier.issn0142-0615
dc.identifier.issn1879-3517
dc.identifier.urihttps://doi.org/10.1016/j.ijepes.2015.02.036
dc.identifier.urihttps://hdl.handle.net/20.500.12462/7516
dc.descriptionBalcı, Murat Erhanen_US
dc.description.abstractIn the literature, it is well known that transformers and cables have excessive losses or overheating under non-sinusoidal current conditions. Accordingly, they have reduced current carrying capabilities (or loading capabilities) for that kind of conditions. This paper aims to employ passive filters for the effective utilization of the cables and transformers in the non-sinusoidal systems. Consequently, an optimal passive filter design approach is provided to maximize the power factor expression, which takes into account frequency-dependent line losses, under non-sinusoidal background voltage and line current conditions. The individual and total harmonic distortion limits placed in IEEE standard 519 are taken into account as constraints for the proposed approach. Besides, keeping the load's displacement power factor at an adequate range is desired by the proposed approach. The proposed approach and the traditional optimal passive filter design approach, which aims to maximize the classical power factor expression, are comparatively evaluated for an industrial power system with a group of linear and non-linear loads, overhead transmission lines, cables and a transformer. Numerical results show that the proposed one has a considerable advantage in the improvement of the total supply line loss and the transformer's loading capability under non-sinusoidal conditions when compared to the traditional one. On the other hand, for the simulated system cases, both approaches lead to almost the same current carrying capability value of the cables.en_US
dc.description.sponsorshipTurkish Republic Ministry of Science, Industry and Technology BEST Transformers Co. - 01008.STZ.2011-2en_US
dc.language.isoengen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.isversionof10.1016/j.ijepes.2015.02.036en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectHarmonic Distortionen_US
dc.subjectNon-Sinusoidal Conditionsen_US
dc.subjectC-Type Filtersen_US
dc.subjectOptimal Designen_US
dc.subjectCable Deratingen_US
dc.subjectTransformer Deratingen_US
dc.titleEffective utilization of cables and transformers using passive filters for non-linear loadsen_US
dc.typearticleen_US
dc.relation.journalInternational Electronic Journal of Power & Energy Systemsen_US
dc.contributor.departmentMühendislik-Mimarlık Fakültesien_US
dc.contributor.authorID0000-0001-8418-8917en_US
dc.contributor.authorID0000-0003-2546-6352en_US
dc.identifier.volume71en_US
dc.identifier.startpage344en_US
dc.identifier.endpage350en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster