Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorİrtem, Erdal
dc.contributor.authorHasgül, Umut
dc.date.accessioned2019-10-16T10:38:10Z
dc.date.available2019-10-16T10:38:10Z
dc.date.issued2009en_US
dc.identifier.issn0887-3828
dc.identifier.issn1943-5509
dc.identifier.urihttps://doi.org/10.1061/(ASCE)CF.1943-5509.0000047
dc.identifier.urihttps://hdl.handle.net/20.500.12462/6867
dc.description.abstractThe aim of the study is to compare and evaluate structural response demands obtained from nonlinear static analysis procedures (NSPs) which are displacement coefficient method (DCM) recommended in FEMA 356 and capacity spectrum method (CSM) recommended in ATC 40. For these reasons, three of three-dimensional low-rise RC buildings with different characteristics are investigated. In order to determine nonlinear behavior of the buildings under lateral loads, the base shear-roof displacement relationships (capacity curves) are obtained by pushover analysis including P-delta effects. Then by considering four different seismic hazard levels, building performances are determined by using the CSM and by using from DCM results determined in a previous study. In order to determine performance levels of the buildings, maximum beam and column plastic rotation demands and maximum story drift demands are determined in the related maximum displacement demands. Plastic strains in the equivalent diagonal struts, representing the nonstructural infill walls, are also determined, similarly. Comparing structural response quantities (such as plastic rotations, story drifts, etc.) obtained from the NSPs for considered low-rise RC buildings, effects of different NSPs in performance evaluations of the buildings are investigated comparatively, as well.en_US
dc.language.isoengen_US
dc.publisherAsce-Amer Soc Civil Engineersen_US
dc.relation.isversionof10.1061/(ASCE)CF.1943-5509.0000047en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectConstruction & Building Technologyen_US
dc.subjectEngineeringen_US
dc.titleInvestigation of effects of nonlinear static analysis procedures to performance evaluation on low-rise rc buildingsen_US
dc.typearticleen_US
dc.relation.journalJournal of Performance of Constructed Facilitiesen_US
dc.contributor.departmentMühendislik Mimarlık Fakültesien_US
dc.identifier.volume23en_US
dc.identifier.issue6en_US
dc.identifier.startpage456en_US
dc.identifier.endpage466en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster