Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorBerksoy, Emel Ataş
dc.contributor.authorBağ, Özlem
dc.contributor.authorYazıcı, Selcuk
dc.contributor.authorÇelik, Tanju
dc.date.accessioned2019-08-07T08:54:00Z
dc.date.available2019-08-07T08:54:00Z
dc.date.issued2018en_US
dc.identifier.issn0025-7974
dc.identifier.issn1536-5964
dc.identifier.urihttps://doi.org/10.1097/MD.0000000000009737
dc.identifier.urihttps://hdl.handle.net/20.500.12462/5938
dc.descriptionYazıcı, Selçuk (Balikesir Author)en_US
dc.description.abstractWe compared the accuracy and utility of 3 infrared (IFR) thermographs fitted with axillary digital thermometers used to measure temperature in febrile and afebrile children admitted to an emergency triage room. A total of 184 febrile and 135 afebrile children presenting to a triage room were consecutively evaluated. Axillary temperature was recorded using a digital electronic thermometer. Simultaneously, IFR skin scans were performed on the forehead, the neck (over the carotid artery), and the nape by the same nurse. Fever was defined as an axillary temperature >= 37.5 degrees C. The temperature readings at the 4 sites were compared. For all subjects, the median axillary temperature was 37.7 +/- 1.5 degrees C, the IFR forehead temperature was 37 +/- 1.1 degrees C, the IFR neck temperature was 37.6 +/- 1.5 degrees C, and the IFR nape temperature was 37 +/- 1.2 degrees C. A Bland-Altman plot of the differences suggested that all agreements between IFR and axillary measures were poor (the latter measure was considered the standard). The forehead measurements had a sensitivity of 88.6% and a specificity of 60% in patients with temperatures >= 36.75 degrees C. The sensitivities of the neck measurement at cut-offs of >= 37.35 degrees C and >= 36.95 were 95.5% and 78.8% for those aged 2 to 6 years. Thus, 11.4% of febrile subjects were missed when forehead measurements were performed. An IFR scan over the lateral side of neck is a reliable, comfortable, rapid, and noninvasive method for fever screening, particularly in children aged 2 to 6 years, in busy settings such as pediatric triage rooms.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.isversionof10.1097/MD.0000000000009737en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectChilden_US
dc.subjectInfrared Thermographyen_US
dc.subjectPediatric Emergencyen_US
dc.subjectTemperature Measurementen_US
dc.titleUse of noncontact infrared thermography to measure temperature in children in a triage roomen_US
dc.typearticleen_US
dc.relation.journalMedicineen_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorID0000-0002-6526-9460en_US
dc.identifier.volume97en_US
dc.identifier.issue5en_US
dc.identifier.startpage1en_US
dc.identifier.endpage6en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster