dc.description.abstractIn this paper, firstly, optimal sizing and placement of photovoltaic-based distributed generation units (PVDGUs) and passive harmonic filters (PFs) are proposed to improve both the PVDGU hosting capacity and bus voltage profile of the distorted radial distribution systems. The objective of the proposed approach (PA) is defined as minimizing the rms deviation and total harmonic distortion of the bus voltages while maximizing the hosting capacity. Its constraints are considered as bus voltage total and individual harmonic distortion limits placed in IEEE standard 519, permissible bus voltage rms intervals, and the numbers and total powers of the PVDGUs and PFs. Secondly, it is aimed to investigate the performance of the PA on the improvement of the hosting capacity and voltage profile. Thus, for the modified IEEE 33 bus test system containing nonlinear loads, it is comparatively evaluated with a traditional PF planning approach (TA) based on minimization of the total voltage harmonic distortion. Finally, the effects of the harmonic analysis algorithm and PVDGU harmonic model preferences on the solutions of both approaches are also analysed. One of the major conclusions obtained from the analysis is that PA achieves significantly higher PVDGU hosting capacity while providing total voltage harmonic distortion mitigation performance very close to TA. In addition, PA achieves almost the same hosting capacity for all considered harmonic models and harmonic analysis algorithms. However, this is not the case for TA.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s00202-023-01800-yen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectHarmonic Analysisen_US
dc.subjectHosting Capacityen_US
dc.subjectOptimal Placementen_US
dc.subjectOptimal Sizingen_US
dc.subjectPassive Filtersen_US
dc.subjectPhotovoltaic Distributed Generation Unitsen_US
dc.titleImprovement of PV unit hosting capacity and voltage profile in distorted radial distribution systems via optimal sizing and placement of passive filtersen_US
dc.typearticleen_US
dc.relation.journalElectrical Engineeringen_US
dc.contributor.departmentMühendislik Fakültesien_US
dc.contributor.authorID0000-0002-0899-6581en_US
dc.contributor.authorID0000-0001-8418-8917en_US
dc.contributor.authorID0000-0001-6528-3812en_US
dc.identifier.volume105en_US
dc.identifier.issue4en_US
dc.identifier.startpage2185en_US
dc.identifier.endpage2198en_US
dc.relation.tubitakinfo:eu-repo/grantAgreement/TUBITAK/SOBAG/116E110
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster