Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.author, Serpil Paksoy
dc.contributor.authorKavukcu, Gulgun
dc.contributor.authorCevik, Celalettin
dc.contributor.authorDemirpolat, Gülen
dc.contributor.authorErtan, Yeşim
dc.contributor.authorTuna, Lale
dc.date.accessioned2024-02-05T15:59:04Z
dc.date.available2024-02-05T15:59:04Z
dc.date.issued2022
dc.identifier.issn1016-9113
dc.identifier.issn2147-6500
dc.identifier.urihttps://doi.org/
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1121250
dc.identifier.urihttps://hdl.handle.net/20.500.12462/14347
dc.description.abstractAim: To examine the diagnostic performance of virtual touch tissue quantification (VTQ) mode of Acoustic Radiation Force Impulse (ARFI) elastography imaging in differentiating benign and malignant thyroid nodules. Materials and Methods: Two hundred four solid and mostly solid nodules >5mm were prospectively evaluated with ultrasonography, VTQ mode of ARFI elastography, fine needle aspiration biopsy, and when indicated with tissue pathology. Three shear-wave velocities (SWV) measurements were done in 196 nodules. The SWV ratio for each nodule was calculated as the mean value of the SWV of the nodule divided by the mean value of the adjacent parenchyma. The diagnostic performance of SWV value and SWV-ratio were assessed by a receiver-operating characteristic (ROC) curve analysis. Results: The mean SWV value in the normal parenchyma, in benign and malign thyroid nodules, were 2.13±0.44 m/s, 2.06±0.80 m/s, and 2.06±0.88 m/s respectively. The SWV-ratios were 0.97±0.37 for benign thyroid nodules and 1.02±0.40 for malignant thyroid nodules. There was no significant difference between benign and malign nodules in terms of mean SWV values (t=0.008) (P=0.994) or SWV-ratios (t =0.596; P=0.527). No cut-off point was found to predict malignancy. In subgroup analysis, AUCs for the SWV and SWV-ratio were significantly different between nodules ?10 mm and those ?10 mm, but not with any other two groups (all P>0.05) (Table-2). The cutoff points for the differential diagnosis were 2.59 m/s for SWV and 1.0 for SWV- ratio respectively for nodules <10 mm. Conclusion: VTQ mode of ARFI imaging does not have a good diagnostic performance for detecting malignancy and cannot contribute to reducing unnecessary thyroid biopsies.en_US
dc.language.isoengen_US
dc.relation.ispartofEge Tıp Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleARFI elastography for differentiating malignant and benign thyroid nodulesen_US
dc.typearticleen_US
dc.contributor.departmentBalıkesir Üniversitesien_US
dc.identifier.volume61en_US
dc.identifier.issue3en_US
dc.identifier.startpage350en_US
dc.identifier.endpage359en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.buozeltrdizinidealen_US]
dc.department-tempBalıkesir Üniversitesi, Tıp Fakültesi, Patoloji Anabilim Dalı, Balıkesir, Türkiye Ege Üniversitesi, Tıp Fakültesi, Radyoloji Anabilim Dalı, İzmir, Türkiye Balıkesir Üniversitesi, Sağlık Bilimleri Fakültesi, Çağış Yerleşkesi, Halk Sağlığı Hemşireliği Anabilim Dalı, Balıkesir, Türkiye Balıkesir Üniversitesi, Tıp Fakültesi, Çağıs Yerleskesi, Radyoloji Anabilim Dalı, Balıkesir, Türkiye Ege Üniversitesi, Tıp Fakültesi, Patoloji Anabilim Dalı, İzmir, Türkiye Kırklareli Eğitim ve Araştırma Hastanesi, Radyoloji Anabilim Dalı, Kırklareli, Türkiyeen_US
dc.identifier.trdizinid1121250en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster