dc.description.abstractSuitability evaluation of a location for solar power generation plant installation requires long-term measurements and calculations. Since the energy production values and project power of solar power plant (SPP) directly affect the return period of the project cost. It is of considerable importance to make the calculations correctly. The effects of the DC/AC ratio, determining in an inverter selection, is a crucial parameter in determining the sizing of SPP. In this study, a model was used to find the closest estimation values. Irradiance values coming to SPP in Balıkesir/Turkey were simulated and DC energy at the inverter input was calculated. The results obtained from the calculation were compared with actual production values. To determine the optimum DC/AC ratio of the existing installed SPP system, calculations were made with two different methods. Energy production estimation values are calculated for different angles and DC/AC rated inverters. It is vital that the SPP consists of two groups with different directions and the same capacities in terms of comparing the accuracy of the calculation. Energy production calculations, including the hourly meteorological data and catalog values of the system, in the developed model are desired to provide the closest prediction values for energy production of the real system. The open_US
dc.language.isoengen_US
dc.relation.ispartofCelal Bayar Üniversitesi Fen Bilimleri Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectClippingen_US
dc.subjectDC/AC Ratioen_US
dc.subjectGriden_US
dc.subjectPerformance Analysisen_US
dc.subjectSizing Ratioen_US
dc.subjectSolar Energyen_US
dc.titleDetermination of optimal DC|AC ratio for grid-connected photovoltaic systemsen_US
dc.typearticleen_US
dc.contributor.departmentBalıkesir Üniversitesien_US
dc.identifier.volume19en_US
dc.identifier.issue1en_US
dc.identifier.startpage19en_US
dc.identifier.endpage29en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.buozeltrdizinidealen_US]
dc.department-tempBalıkesir Üniversitesi, Elektrik-Elektronik Mühendisliği Bölümü, Balıkesir, Türkiye Balıkesir Üniversitesi, Elektrik-Elektronik Mühendisliği Bölümü, Balıkesir, Türkiyeen_US
dc.identifier.trdizinid1161809en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster