Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSargın, Serdar
dc.contributor.authorAtik, Aziz
dc.contributor.authorUlusal, Ali Engin
dc.contributor.authorAslan, Ahmet
dc.contributor.authorKülünk, Mert İsmail
dc.date.accessioned2023-09-25T08:31:59Z
dc.date.available2023-09-25T08:31:59Z
dc.date.issued2022en_US
dc.identifier.issn1067-2516 / 1542-2224
dc.identifier.urihttps://doi.org/10.1053/j.jfas.2021.11.025
dc.identifier.urihttps://hdl.handle.net/20.500.12462/13426
dc.descriptionSargın, Serdar (Balikesir Author)en_US
dc.description.abstractAnkle arthrosis may be an unexpected potential result in syndesmotic injuries because of instability and malreduction. For anatomical reduction and stabilization, a reliable and stable reference point is crucial to correctly place syndesmotic screw. The aim of this study was to determine a reliable reference point and to quantify the ideal angle for placement of the screw. In this prospective cohort study, 99 healthy volunteers underwent right ankle magnetic resonance (MR) imaging. On the axial sections, the ideal axis of the syndesmotic screw and other reference points were depicted with 4 lines and 2 angles which were evaluated at the level 2 cm above the tibial plafond. Values were recorded by 2 independent observers to assess for interobserver reliability. The mean value of syndesmotic screw position according to the ground line was 28° § 6.4° like Arbeitsgemeinschaft fur Osteosyn- € thesefragen suggestion. Furthermore, it was determined that the syndesmotic screw could be placed more precisely in the position when placed at an angle of 26.2° § 1.1° with the axis perpendicular to the line passing through the anterior tibial and Achilles tendons. Ideal syndesmotic screw positioning must be stable enough in case not to be affected by lower extremity alignment deficiencies or foot deformities. So, the anterior tibial and Achilles tendons can be used as reproducible and reliable landmarks for the placement of syndesmotic screws.en_US
dc.language.isoengen_US
dc.publisherElsevier Sci Incen_US
dc.relation.isversionof10.1053/j.jfas.2021.11.025en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectAchilles Tendonen_US
dc.subjectAngleen_US
dc.subjectAnterior Tibial Tendonen_US
dc.subjectScrewen_US
dc.subjectSyndesmoticen_US
dc.titleReproducible and reliable method for syndesmotic screw fixation: An MRI-based cross-sectional image analysisen_US
dc.typearticleen_US
dc.relation.journalJournal of Foot and Ankle Surgeryen_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorID0000-0003-4939-8745en_US
dc.contributor.authorID0000-0001-5797-1287en_US
dc.identifier.volume61en_US
dc.identifier.issue4en_US
dc.identifier.startpage821en_US
dc.identifier.endpage826en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster