dc.contributor.author | Akay, Ebru | |
dc.contributor.author | Atasoy, Deniz | |
dc.contributor.author | Altınkaya, Engin | |
dc.contributor.author | Koç, Ali | |
dc.contributor.author | Ertan, Tamer | |
dc.contributor.author | Karaman, Hatice | |
dc.contributor.author | Çağlar, Erkan | |
dc.date.accessioned | 2022-08-04T10:44:52Z | |
dc.date.available | 2022-08-04T10:44:52Z | |
dc.date.issued | 2021 | en_US |
dc.identifier.issn | 2234-2400 - 2234-2443 | |
dc.identifier.uri | https://doi.org/10.5946/ce.2020.065 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12462/12417 | |
dc.description | Çağlar, Erkan (Balikesir Author) | en_US |
dc.description.abstract | Background/Aims: Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has been accepted as a reliable tool in diagnosing and staging intra-abdominal tumors. In this study, we aimed to investigate the performance of EUS-FNA in the evaluation of liver masses and its impact on patient management and procedure-related complications retrospectively.
Methods: Data of patients who underwent EUS-FNA biopsies due to liver masses between November 2017 and July 2018 were retrieved retrospectively. Biopsies were performed using 22-G needles. The demographics, EUS-FNA results, sensitivity and specificity of the procedure, negative predictive value, positive predictive value, and specimen sufficiency rates were assessed.
Results: A total of 25 patients (10 females) were included in the study. The mean age was 62.73 +/- 15.2 years. The mean size of the masses was 34.50 +/- 16.04 mm. The technical success rate was 88%. During the EUS-FNA procedure, each patient had only one pass with 94.45% of aspirate sufficiency rate and 86.3% of biopsy sufficiency rate. The diagnostic accuracy rate was 86.3%. There were no complications.
Conclusions: For the evaluation of liver masses, EUS-FNA using a 22-G needle with even one pass had high aspiration and biopsy success rates accompanied with high diagnostic accuracy rates. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Kore | en_US |
dc.relation.isversionof | 10.5946/ce.2020.065 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Clinical Management | en_US |
dc.subject | Diagnostic Accuracy | en_US |
dc.subject | Endoscopic Ultrasound | en_US |
dc.subject | Fine Needle Aspiration | en_US |
dc.subject | Liver Mass | en_US |
dc.title | Endoscopic ultrasound-guided fine needle aspiration using a 22-g needle for hepatic lesions: Single-center experience | en_US |
dc.type | article | en_US |
dc.relation.journal | Korean Soc Gastrointestinal Endoscopy | en_US |
dc.contributor.department | Tıp Fakültesi | en_US |
dc.identifier.volume | 54 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 404 | en_US |
dc.identifier.endpage | 412 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |