Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKılınç, Rabia Mihriban
dc.contributor.authorAçan, Ahmet Emrah
dc.contributor.authorTürk, Gamze
dc.contributor.authorKılınç, Cem Yalın
dc.contributor.authorYeniçeri, İbrahim Önder
dc.date.accessioned2022-07-01T11:46:31Z
dc.date.available2022-07-01T11:46:31Z
dc.date.issued2021en_US
dc.identifier.issn0284-1851-1600-0455
dc.identifier.urihttps://doi.org/10.1177/02841851211021035
dc.identifier.urihttps://hdl.handle.net/20.500.12462/12379
dc.descriptionAçan, Ahmet Emrah (Balikesir Author)en_US
dc.description.abstractBackground Osteoporosis is associated with decreases in bone mineral density (BMD) and is diagnosed using dual-energy X-ray absorptiometry (DXA). Computed tomography (CT), performed in routine practice, can also be used to evaluate bone quality without additional cost. Purpose To determine whether Hounsfield units (HU), a standardized CT attenuation coefficient, measured from the femoral head correlated with DXA-measured BMD. Material and Methods We evaluated 82 patients (14 men, 68 women; mean age, 67 years) undergoing femoral DXA and CT (non-enhanced abdominopelvic and hip scans) with 130 kV to determine whether HU correlated with T-scores. HU were measured by two radiologists using the largest spherical region of interest including the medullary bone of the femoral head from the junction point of the most caudal section of the femoral head with the femoral neck in 5-mm axial sections. The correlations of both sides' HU values with their ages and DXA femur T-score were evaluated. Results HU values obtained from both femoral heads showed significant variation between the osteoporotic and non-osteoporotic groups (both P = 0.000) and strongly correlated with each other and DXA femur T-scores (left r = 0.75, right r = 0.73, respectively). In ROC curve analysis, predictive power of left HU values in identifying patients with osteoporotic femur DXA T-score was 0.905, and for right HU values it was 0.924. Osteoporosis cutoff values were 198 HU and 204 HU for the left and right hips, respectively. Conclusions HU obtained from CT performed in routine practice correlated with the DXA scores, thus providing an alternative method to determine regional bone quality without additional cost. This may be useful when choosing a fixation method, especially in trauma cases with already-performed abdominopelvic or pelvic CT in emergency services.en_US
dc.language.isoengen_US
dc.publisherSage Publications Ltden_US
dc.relation.isversionof10.1177/02841851211021035en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectOsteoporosisen_US
dc.subjectDual-energy X-ray Absorptiometryen_US
dc.subjectBone Qualityen_US
dc.subjectT-scoresen_US
dc.subjectHounsfield Uniten_US
dc.titleEvaluation of femoral head bone quality by Hounsfield units: a comparison with dual-energy X-ray absorptiometryen_US
dc.typearticleen_US
dc.relation.journalActa Radiologicaen_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorID0000-0001-7116-8773en_US
dc.contributor.authorID0000-0002-5374-9731en_US
dc.contributor.authorID0000-0002-6845-5496en_US
dc.identifier.volume63en_US
dc.identifier.issue7en_US
dc.identifier.startpage933en_US
dc.identifier.endpage941en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster