Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.advisorNakiboğlu, Nuri
dc.contributor.authorErdinç, Aysel
dc.date.accessioned2019-10-01T13:09:29Z
dc.date.available2019-10-01T13:09:29Z
dc.date.issued2019en_US
dc.date.submitted2019
dc.identifier.citationErdinç, Aysel. Eriochrome black T modifiye kalem grafit elektrot ile voltammetrik atorvastatin tayini. Yayınlanmamış yüksek lisans tezi. Balıkesir Üniversitesi Fen Bilimleri Enstitüsü, 2019.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12462/6542
dc.descriptionBalıkesir Üniversitesi, Fen Bilimleri Enstitüsü, Kimya Ana Bilim Dalıen_US
dc.description.abstractBu çalışmada poli Eriochrome Black T modifiye Kalem Grafit Elektrodu (pEBT/PGE) ile ilaç tabletlerinde Atorvastatin (ATOR) tayini için yeni bir voltammetrik yöntemin çalışma koşulları incelenmiştir. Hazırlanan EBT/PGE elektrodu ve yalın PGE elektrodunun K3Fe(CN)6 çözeltisindeki döngüsel voltammetrik davranışları, ATOR çözeltisindeki differansiyel puls voltammogramları ve SEM görüntüleri karşılaştırılarak karakterize edilmiştir. Farklı tarama hızlarında K3Fe(CN)6 çözeltisindeki döngüsel voltammogramlar alınarak çizilen Ip - V1/2 grafiğinden elektrot alanı 1,037 ± 0,019 olarak hesaplanmıştır. Ayrıca 1×10-4 M ATOR çözeltisinin 0,04 M BR tamponlu (pH= 5) ortamda farklı tarama hızlarında döngüsel voltammogramları alınarak çizilen Ip- V, Ip- V1/2 ve log Ip- logV grafiklerinden ATOR’un EBT/PGE elektrottaki yükseltgenme tepkimesinin diffüzyon kontrollü olduğu anlaşılmıştır. Buna ek olarak EP - V, EP - logV grafiklerinden yararlanarak ATOR’un formal potansiyeli 1,0453 V, elektrot tepkimesinde aktarılan elektron sayısı 2 ve tepkimenin heterojen hız sabiti 865 s-1 olarak hesaplanmıştır. Yöntemin doğrusal aralığı 4×10-6 M - 2,5×10-4 M, kalibrasyon grafiğinin doğru denklemi Ip (µA) = 0,0133 ( ± 7,44×10-4 ) CATOR + 0,0538 ( ± 0,062 ) ve varyasyon katsayısı, R2, 0,9961 olarak bulunmuştur. Yöntemin dedeksiyon limiti ve tayin sınırı 8×10-6 M ATOR derişimi için elde edilen pik akımlarının standart sapması (N = 5) esas alınarak (3s ve 10s) sırasıyla 2×10-6 M ve 6,7×10-6 M olarak hesaplanmıştır. Yöntem piyasada bulunan tabletlerde ATOR tayini için uygulanmış yüzde gerçeklik (%G), yüzde bias ve yüzde bağıl standart sapma sırasıyla %96.8, %3.2 ve %2.58 olarak bulunmuştur. Ayrıca bu tablet üzerine standart ATOR çözeltisinden eklenen örneklerdeki geri kazanımlar % 107 ve % 104 olarak belirlenmiştir. Yöntemin tabletlerde ATOR tayini için camsı karbon ve cıva esaslı elektrotlara göre daha basit ve ucuz olması yanında ve doğru sonuç da verdiği gözlenmiştir.en_US
dc.description.abstractIn this study, the working conditions of a new voltammetric method for determination of Atorvastatin (ATOR) in drug tablets with poly Eriochrome Black T modified Pencil Graphite Electrode (pEBT / PGE) were investigated. The cyclic voltammetric behaviors of the prepared EBT / PGE electrode and bare PGE electrode in K3Fe(CN)6 solution were characterized by comparing the differential pulse voltammograms and SEM images in the ATOR solution. The electrode area was calculated as 1,037 ± 0,019 from the Ip- V1/2 graph drawn by taking cyclic voltammograms in K3Fe(CN)6 solution at different scanning rates. In addition, cyclic voltammograms for different scanning rates were also recorded in 1×10-4 M ATOR solution in the presence of 0.04 M BR buffered (pH = 5). Ip- V, Ip- V1/2 and log Ip- logV graphs were drawn and the electrode oxidation reaction of ATOR at EBT / PGE was found to be diffusion controlled. In addition, using the EP - V and EP - logV graphs, the formal potential of ATOR was calculated as 1,0453 V, and the number of electrons transferred and the heterogeneous rate constant of the reaction were calculated as 2 and 865 s-1, respectively. The linear range of the method was 4×10-6 M – 2,5×10-4 M, and equation of the calibration graph was Ip (μA) = 0,0133 ( ± 7,44×10-4 ) CATOR + 0,0538 ( ± 0,062 ) (R2= 0.9961). The detection limit and the limit of quantification of the method based on the standard deviation (N = 5) of the peak currents obtained for the concentration of 8×10-6 M ATOR were calculated as 2x10-6 M and 6,7x10-6 M, respectively,. The trueness (% T), bias and relative standard deviation of the method were found to be 96.8%, 3.2% and 2.58%, respectively. In addition, the recoveries obtained from two samples spiked with the standard ATOR solution were determined as 107% and 104%. It was observed that the method was simpler and cheaper than the glassy carbon and mercury based electrodes for the determination of ATOR in the tablets as well as giving the good accuracy.en_US
dc.description.sponsorshipBu tez çalışması Balıkesir Üniversitesi Bilimsel Araştırma Projeleri Birimi tarafından 2018/17 nolu proje ile desteklenmiştir.en_US
dc.language.isoturen_US
dc.publisherBalıkesir Üniversitesi Fen Bilimleri Enstitüsüen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAtorvastatinen_US
dc.subjectEBTen_US
dc.subjectKalem Grafit Elektroten_US
dc.subjectDiferansiyel Puls Voltammetrisien_US
dc.subjectModifiye Elektroten_US
dc.subjectPencil Graphite Elektrodeen_US
dc.subjectDifferantial Pulse Voltammetryen_US
dc.subjectModified Electrodeen_US
dc.titleEriochrome black T modifiye kalem grafit elektrot ile voltammetrik atorvastatin tayinien_US
dc.title.alternativeVoltammetric determination of atorvastatin with eriochrome black T modified pencil graphite electrodeen_US
dc.typemasterThesisen_US
dc.contributor.departmentFen Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster